Improve the Efficiency of Surgery for Femoral Shaft Fractures with A Novel Instrument: A Randomized Controlled Trial.


ABSTRACT:

Objective

To improve the efficacy of closed reduction and wire guiding during intramedullary nail internal fixation in femoral shaft fractures.

Methods

A novel instrument was designed and manufactured. Sixty-eight patients were enrolled from February 2011 to December 2013. The instrument designed was used during the operation in the experimental group, but not in the control group.

Results

All patients exhibited fracture union, excluding 1 patient in the experimental group and 2 in the control group who had non-union; all of whom achieved fracture union with reoperation. There were no statistically significant differences in operative blood loss or duration of hospital stay between the groups (P > 0.05). The operative time, frequency of wire drilling, and number of open reduction cases, were significantly smaller in the experimental group than in the control group (P < 0.05).

Conclusion

Femoral shaft fractures are difficult to reduce using general methods; the novel instrument showed high clinical value and proved effective and safe in assisting with closed reduction and intramedullary nail fixation for femoral shaft fractures.

Trial registration

ChiCTR ChiCTR-ICR-15007335.

SUBMITTER: Xu H 

PROVIDER: S-EPMC4846024 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improve the Efficiency of Surgery for Femoral Shaft Fractures with A Novel Instrument: A Randomized Controlled Trial.

Xu Haitao H   Yin Wenjing W   Hsu Peichun P   Qin Hui H   An Zhiquan Z   Zhang Changqing C   Sheng Jiagen J  

PloS one 20160426 4


<h4>Objective</h4>To improve the efficacy of closed reduction and wire guiding during intramedullary nail internal fixation in femoral shaft fractures.<h4>Methods</h4>A novel instrument was designed and manufactured. Sixty-eight patients were enrolled from February 2011 to December 2013. The instrument designed was used during the operation in the experimental group, but not in the control group.<h4>Results</h4>All patients exhibited fracture union, excluding 1 patient in the experimental group  ...[more]

Similar Datasets

| S-EPMC6521597 | biostudies-literature
| S-EPMC5530786 | biostudies-other
| S-EPMC2663330 | biostudies-literature
| S-EPMC5580418 | biostudies-literature
| S-EPMC2267537 | biostudies-other
| S-EPMC4761270 | biostudies-literature
| S-EPMC6613852 | biostudies-literature
| S-EPMC7218498 | biostudies-literature
| S-EPMC3490887 | biostudies-other
| S-EPMC5899094 | biostudies-literature