Free-breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T.


ABSTRACT: To develop a free-breathing variable flip angle (VFA) balanced steady-state free precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate (SAR) at 3 Tesla.Free-breathing VFA (FB-VFA) images in the short-axis and four-chamber views were acquired using an optimal VFA scheme, then compared with conventional breath-hold constant flip angle (BH-CFA) acquisitions. Two cardiac MRI experts used a 5-point scale to score images from healthy subjects (N = 10). The left ventricular ejection fraction, end diastolic volume (LVEDV), end systolic volume, stroke volume (LVSV), and end diastolic myocardial mass (LVEDM) were determined by manual contour analysis for BH-CFA and FB-VFA. A pilot evaluation of FB-VFA was performed in one patient with Duchenne muscular dystrophy.FB-VFA SAR was 25% lower than BH-CFA with similar blood-myocardium contrast. The qualitative FB-VFA score was lower than the BH-CFA for the short-axis (3.1 ± 0.5 versus 4.3 ± 0.8; P < 0.05) and the four-chamber view (3.4 ± 0.4 versus 4.6 ± 0.6; P < 0.05). The LVEDV and the LVSV were 5% and 12% larger (P < 0.05) for FB-VFA compared with BH-CFA. There was no difference in LVEDM.FB-VFA bSSFP cardiac cine imaging decreased the SAR at 3T with image quality sufficient to perform cardiac functional analysis. Magn Reson Med 76:1210-1216, 2016. © 2015 Wiley Periodicals, Inc.

SUBMITTER: Srinivasan S 

PROVIDER: S-EPMC4848168 | biostudies-literature | 2016 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Free-breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T.

Srinivasan Subashini S   Kroeker Randall M RM   Gabriel Simon S   Plotnik Adam A   Godinez Sergio R SR   Hu Peng P   Halnon Nancy N   Finn J Paul JP   Ennis Daniel B DB  

Magnetic resonance in medicine 20151028 4


<h4>Purpose</h4>To develop a free-breathing variable flip angle (VFA) balanced steady-state free precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate (SAR) at 3 Tesla.<h4>Methods</h4>Free-breathing VFA (FB-VFA) images in the short-axis and four-chamber views were acquired using an optimal VFA scheme, then compared with conventional breath-hold constant flip angle (BH-CFA) acquisitions. Two cardiac MRI experts used a 5-point scale to score images from healthy su  ...[more]

Similar Datasets

| S-EPMC7048216 | biostudies-literature
| S-EPMC7573656 | biostudies-literature
| S-EPMC4801698 | biostudies-literature
| S-EPMC3871989 | biostudies-literature
| S-EPMC5689072 | biostudies-literature
| S-EPMC7611405 | biostudies-literature
| S-EPMC10140109 | biostudies-literature
| S-EPMC6021016 | biostudies-literature
| S-EPMC6510595 | biostudies-literature
| S-EPMC4362865 | biostudies-literature