Validation of the Filovirus Plaque Assay for Use in Preclinical Studies.


ABSTRACT: A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) variant and Ebola Virus Kikwit (EBOV) variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID). The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV) of ?30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay's precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP) serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies.

SUBMITTER: Shurtleff AC 

PROVIDER: S-EPMC4848606 | biostudies-literature | 2016 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of the Filovirus Plaque Assay for Use in Preclinical Studies.

Shurtleff Amy C AC   Bloomfield Holly A HA   Mort Shannon S   Orr Steven A SA   Audet Brian B   Whitaker Thomas T   Richards Michelle J MJ   Bavari Sina S  

Viruses 20160421 4


A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4) studies. After standardization studies were completed, Good Laboratory Practices (GLP)-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV) var  ...[more]

Similar Datasets

| S-EPMC7826780 | biostudies-literature
| S-EPMC8474009 | biostudies-literature
| S-EPMC4685718 | biostudies-literature
| S-EPMC2976089 | biostudies-literature
| S-EPMC5942582 | biostudies-literature
| S-EPMC3252361 | biostudies-literature
| S-EPMC6472792 | biostudies-literature
| S-EPMC3273325 | biostudies-literature
| S-EPMC11237447 | biostudies-literature
| S-EPMC5960426 | biostudies-literature