Influences of Head Motion Regression on High-Frequency Oscillation Amplitudes of Resting-State fMRI Signals.


ABSTRACT: High-frequency oscillations (HFOs, >0.1 Hz) of resting-state fMRI (rs-fMRI) signals have received much attention in recent years. Denoising is critical for HFO studies. Previous work indicated that head motion (HM) has remarkable influences on a variety of rs-fMRI metrics, but its influences on rs-fMRI HFOs are still unknown. In this study, we investigated the impacts of HM regression (HMR) on HFO results using a fast sampling rs-fMRI dataset. We demonstrated that apparent high-frequency (?0.2-0.4 Hz) components existed in the HM trajectories in almost all subjects. In addition, we found that individual-level HMR could robustly reveal more between-condition (eye-open vs. eye-closed) amplitude differences in high-frequency bands. Although regression of mean framewise displacement (FD) at the group level had little impact on the results, mean FD could significantly account for inter-subject variance of HFOs even after individual-level HMR. Our findings suggest that HM artifacts should not be ignored in HFO studies, and HMR is necessary for detecting HFO between-condition differences.

SUBMITTER: Yuan BK 

PROVIDER: S-EPMC4881380 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Influences of Head Motion Regression on High-Frequency Oscillation Amplitudes of Resting-State fMRI Signals.

Yuan Bin-Ke BK   Zang Yu-Feng YF   Liu Dong-Qiang DQ  

Frontiers in human neuroscience 20160526


High-frequency oscillations (HFOs, >0.1 Hz) of resting-state fMRI (rs-fMRI) signals have received much attention in recent years. Denoising is critical for HFO studies. Previous work indicated that head motion (HM) has remarkable influences on a variety of rs-fMRI metrics, but its influences on rs-fMRI HFOs are still unknown. In this study, we investigated the impacts of HM regression (HMR) on HFO results using a fast sampling rs-fMRI dataset. We demonstrated that apparent high-frequency (∼0.2-0  ...[more]

Similar Datasets

| S-EPMC7238750 | biostudies-literature
| S-EPMC8187680 | biostudies-literature
| S-EPMC4712830 | biostudies-literature
| S-EPMC8046067 | biostudies-literature
| S-EPMC4923135 | biostudies-literature
| S-EPMC3615090 | biostudies-literature
| S-EPMC5834724 | biostudies-other
| S-EPMC5745814 | biostudies-literature
| S-EPMC5489212 | biostudies-other
| S-EPMC4043948 | biostudies-literature