Unknown

Dataset Information

0

Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects.


ABSTRACT: Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible articles consisting of 1140 AAD subjects and 3860 non-AAD subjects, the diagnostic odds ratio was 28.5 (95% CI 17.6-46.3, I(2)?=?17.4%) and the area under curve was 0.946 (95% CI 0.903-0.994). Based on 833 AAD subjects and 1994 non-AAD subjects constituting 12 studies that used the cutoff value of 500?ng/ml, the sensitivity was 0.952 (95% CI 0.901-0.978), the specificity was 0.604 (95% CI 0.485-0.712), positive likelihood ratio was 2.4 (95% CI 1.8-3.3), and negative likelihood ratio was 0.079 (95% CI 0.036-0.172). Sensitivity analysis using data of three high-quality studies almost replicated these results. In conclusion, D-dimer has very good overall accuracy. D-dimer <500?ng/ml largely decreases the possibility of AAD. D-dimer >500?ng/ml moderately increases the possibility of AAD.

SUBMITTER: Watanabe H 

PROVIDER: S-EPMC4882530 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic test accuracy of D-dimer for acute aortic syndrome: systematic review and meta-analysis of 22 studies with 5000 subjects.

Watanabe Hiroki H   Horita Nobuyuki N   Shibata Yuji Y   Minegishi Shintaro S   Ota Erika E   Kaneko Takeshi T  

Scientific reports 20160527


Diagnostic test accuracy of D-dimer for acute aortic dissection (AAD) has not been evaluated by meta-analysis with the bivariate model methodology. Four databases were electrically searched. We included both case-control and cohort studies that could provide sufficient data concerning both sensitivity and specificity of D-dimer for AAD. Non-English language articles and conference abstract were allowed. Intramural hematoma and penetrating aortic ulcer were regarded as AAD. Based on 22 eligible a  ...[more]

Similar Datasets

| S-EPMC8246725 | biostudies-literature
| S-EPMC7647361 | biostudies-literature
| S-EPMC3851548 | biostudies-literature
| S-EPMC4115600 | biostudies-literature
| S-EPMC4105799 | biostudies-other
| S-EPMC6921417 | biostudies-literature
| S-EPMC7668444 | biostudies-literature
| S-EPMC7430004 | biostudies-literature
| S-EPMC4785536 | biostudies-other
| S-EPMC8103840 | biostudies-literature