Unknown

Dataset Information

0

Optical diffraction for measurements of nano-mechanical bending.


ABSTRACT: We explore and exploit diffraction effects that have been previously neglected when modelling optical measurement techniques for the bending of micro-mechanical transducers such as cantilevers for atomic force microscopy. The illumination of a cantilever edge causes an asymmetric diffraction pattern at the photo-detector affecting the calibration of the measured signal in the popular optical beam deflection technique (OBDT). The conditions that avoid such detection artefacts conflict with the use of smaller cantilevers. Embracing diffraction patterns as data yields a potent detection technique that decouples tilt and curvature and simultaneously relaxes the requirements on the illumination alignment and detector position through a measurable which is invariant to translation and rotation. We show analytical results, numerical simulations and physiologically relevant experimental data demonstrating the utility of the diffraction patterns. We offer experimental design guidelines and quantify possible sources of systematic error in OBDT. We demonstrate a new nanometre resolution detection method that can replace OBDT, where diffraction effects from finite sized or patterned cantilevers are exploited. Such effects are readily generalized to cantilever arrays, and allow transmission detection of mechanical curvature, enabling instrumentation with simpler geometry. We highlight the comparative advantages over OBDT by detecting molecular activity of antibiotic Vancomycin.

SUBMITTER: Hermans RI 

PROVIDER: S-EPMC4891711 | biostudies-literature | 2016 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optical diffraction for measurements of nano-mechanical bending.

Hermans Rodolfo I RI   Dueck Benjamin B   Ndieyira Joseph Wafula JW   McKendry Rachel A RA   Aeppli Gabriel G  

Scientific reports 20160603


We explore and exploit diffraction effects that have been previously neglected when modelling optical measurement techniques for the bending of micro-mechanical transducers such as cantilevers for atomic force microscopy. The illumination of a cantilever edge causes an asymmetric diffraction pattern at the photo-detector affecting the calibration of the measured signal in the popular optical beam deflection technique (OBDT). The conditions that avoid such detection artefacts conflict with the us  ...[more]

Similar Datasets

| S-EPMC3545873 | biostudies-literature
| S-EPMC7679449 | biostudies-literature
| S-EPMC9126882 | biostudies-literature
| S-EPMC4705685 | biostudies-literature
| S-EPMC3684569 | biostudies-literature
| S-EPMC3971819 | biostudies-other
| S-EPMC8034668 | biostudies-literature
| S-EPMC7910307 | biostudies-literature
| S-EPMC6811526 | biostudies-literature
| S-EPMC6035038 | biostudies-literature