MR Imaging of Pulmonary Nodules: Detection Rate and Accuracy of Size Estimation in Comparison to Computed Tomography.


ABSTRACT:

Objective

The aims of this study were to assess the sensitivity of various magnetic resonance imaging (MRI) sequences for the diagnosis of pulmonary nodules and to estimate the accuracy of MRI for the measurement of lesion size, as compared to computed tomography (CT).

Methods

Fifty patients with 113 pulmonary nodules diagnosed by CT underwent lung MRI and CT. MRI studies were performed on 1.5T scanner using the following sequences: T2-TSE, T2-SPIR, T2-STIR, T2-HASTE, T1-VIBE, and T1-out-of-phase. CT and MRI data were analyzed independently by two radiologists.

Results

The overall sensitivity of MRI for the detection of pulmonary nodules was 80.5% and according to nodule size: 57.1% for nodules ?4mm, 75% for nodules >4-6mm, 87.5% for nodules >6-8mm and 100% for nodules >8mm. MRI sequences yielded following sensitivities: 69% (T1-VIBE), 54.9% (T2-SPIR), 48.7% (T2-TSE), 48.7% (T1-out-of-phase), 45.1% (T2-STIR), 25.7% (T2-HASTE), respectively. There was very strong agreement between the maximum diameter of pulmonary nodules measured by CT and MRI (mean difference -0.02 mm; 95% CI -1.6-1.57 mm; Bland-Altman analysis).

Conclusions

MRI yielded high sensitivity for the detection of pulmonary nodules and enabled accurate assessment of their diameter. Therefore it may be considered an alternative to CT for follow-up of some lung lesions. However, due to significant number of false positive diagnoses, it is not ready to replace CT as a tool for lung nodule detection.

SUBMITTER: Cieszanowski A 

PROVIDER: S-EPMC4892605 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

MR Imaging of Pulmonary Nodules: Detection Rate and Accuracy of Size Estimation in Comparison to Computed Tomography.

Cieszanowski Andrzej A   Lisowska Antonina A   Dabrowska Marta M   Korczynski Piotr P   Zukowska Malgorzata M   Grudzinski Ireneusz P IP   Grudzinski Ireneusz P IP   Pacho Ryszard R   Rowinski Olgierd O   Krenke Rafal R  

PloS one 20160603 6


<h4>Objective</h4>The aims of this study were to assess the sensitivity of various magnetic resonance imaging (MRI) sequences for the diagnosis of pulmonary nodules and to estimate the accuracy of MRI for the measurement of lesion size, as compared to computed tomography (CT).<h4>Methods</h4>Fifty patients with 113 pulmonary nodules diagnosed by CT underwent lung MRI and CT. MRI studies were performed on 1.5T scanner using the following sequences: T2-TSE, T2-SPIR, T2-STIR, T2-HASTE, T1-VIBE, and  ...[more]

Similar Datasets

| S-EPMC9834693 | biostudies-literature
| S-EPMC9816753 | biostudies-literature
| S-EPMC8024830 | biostudies-literature
| S-EPMC11002476 | biostudies-literature
| S-EPMC7288754 | biostudies-literature
| S-EPMC4949123 | biostudies-literature
| S-EPMC5717124 | biostudies-literature
| S-EPMC10018993 | biostudies-literature
| S-EPMC11320548 | biostudies-literature
| S-EPMC7007984 | biostudies-literature