Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.


ABSTRACT: Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.

SUBMITTER: McKenzie JH 

PROVIDER: S-EPMC4912006 | biostudies-literature | 2011 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of lot-to-lot repeatability and effect of assay media choice in the recombinant Factor C assay.

McKenzie Jennifer Helen JH   Alwis K Udeni KU   Sordillo Joanne E JE   Kalluri Kesava Srinivas KS   Milton Donald Kirby DK  

Journal of environmental monitoring : JEM 20110509 6


Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and a  ...[more]

Similar Datasets

| S-EPMC6021480 | biostudies-literature
| S-EPMC6711527 | biostudies-literature
| S-EPMC4192584 | biostudies-literature
| S-EPMC6647453 | biostudies-literature
| S-EPMC7369417 | biostudies-literature
| S-EPMC4784438 | biostudies-literature
2014-09-12 | PXD001248 | Pride
2009-05-14 | GSE13860 | GEO
| S-EPMC6919242 | biostudies-literature
| S-EPMC11374653 | biostudies-literature