(Near-Infrared) Fluorescence-Guided Surgery Under Ambient Light Conditions: A Next Step to Embedment of the Technology in Clinical Routine.


ABSTRACT:

Background and purpose

In open surgery procedures, after temporarily dimming the lights in the operation theatre, the Photo Dynamic Eye (PDE) fluorescence camera has, amongst others, been used for fluorescence-guided sentinel node (SN) biopsy procedures. To improve the clinical utility and logistics of fluorescence-guided surgery, we developed and evaluated a prototype modified PDE (m-PDE) fluorescence camera system.

Methods

The m-PDE works under ambient light conditions and includes a white light mode and a pseudo-green-colored fluorescence mode (including a gray-scaled anatomical background). Twenty-seven patients scheduled for SN biopsy for (head and neck) melanoma (n = 16), oral cavity (n = 6), or penile (n = 5) cancer were included. The number and location of SNs were determined following an indocyanine green-(99m)Tc-nanocolloid injection and preoperative imaging. Intraoperatively, fluorescence guidance was used to visualize the SNs. The m-PDE and conventional PDE were compared head-to-head in a phantom study, and in seven patients. In the remaining 20 patients, only the m-PDE was evaluated.

Results

Phantom study: The m-PDE was superior over the conventional PDE, with a detection sensitivity of 1.20 × 10(-11) M (vs. 3.08 × 10(-9) M) ICG in human serum albumin. In the head-to-head clinical comparison (n = 7), the m-PDE was also superior: (i) SN visualization: 100 versus 81.4 %; (ii) transcutaneous SN visualization: 40.7 versus 22.2 %; and (iii) lymphatic duct visualization: 7.4 versus 0 %. Findings were further underlined in the 20 additionally included patients.

Conclusion

The m-PDE enhanced fluorescence imaging properties compared with its predecessor, and provides a next step towards routine integration of real-time fluorescence guidance in open surgery.

SUBMITTER: van den Berg NS 

PROVIDER: S-EPMC4927603 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

(Near-Infrared) Fluorescence-Guided Surgery Under Ambient Light Conditions: A Next Step to Embedment of the Technology in Clinical Routine.

van den Berg Nynke S NS   Miwa Mitsuharu M   KleinJan Gijs H GH   Sato Takayuki T   Maeda Yoshiki Y   van Akkooi Alexander C J AC   Horenblas Simon S   Karakullukcu Baris B   van Leeuwen Fijs W B FW  

Annals of surgical oncology 20160328 8


<h4>Background and purpose</h4>In open surgery procedures, after temporarily dimming the lights in the operation theatre, the Photo Dynamic Eye (PDE) fluorescence camera has, amongst others, been used for fluorescence-guided sentinel node (SN) biopsy procedures. To improve the clinical utility and logistics of fluorescence-guided surgery, we developed and evaluated a prototype modified PDE (m-PDE) fluorescence camera system.<h4>Methods</h4>The m-PDE works under ambient light conditions and inclu  ...[more]

Similar Datasets

| S-EPMC3755013 | biostudies-other
| S-EPMC3775857 | biostudies-literature
| S-EPMC6425328 | biostudies-literature
| S-EPMC6032015 | biostudies-literature
| S-EPMC6241325 | biostudies-literature
| S-EPMC6574176 | biostudies-literature
| S-EPMC6929619 | biostudies-literature
| S-EPMC8171106 | biostudies-literature
| S-EPMC8450770 | biostudies-literature
| S-EPMC6058498 | biostudies-literature