Ontology highlight
ABSTRACT: Objective
To analyze the diagnostic accuracy and trend in screening mammography in Korea.Materials and methods
We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI).Results
We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR.Conclusion
The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.
SUBMITTER: Lee EH
PROVIDER: S-EPMC4936171 | biostudies-literature | 2016 Jul-Aug
REPOSITORIES: biostudies-literature
Lee Eun Hye EH Kim Keum Won KW Kim Young Joong YJ Shin Dong-Rock DR Park Young Mi YM Lim Hyo Soon HS Park Jeong Seon JS Kim Hye-Won HW Kim You Me YM Kim Hye Jung HJ Jun Jae Kwan JK
Korean journal of radiology 20160627 4
<h4>Objective</h4>To analyze the diagnostic accuracy and trend in screening mammography in Korea.<h4>Materials and methods</h4>We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), an ...[more]