Unknown

Dataset Information

0

Intravoxel Incoherent Motion Metrics as Potential Biomarkers for Survival in Glioblastoma.


ABSTRACT: Intravoxel incoherent motion (IVIM) is an MRI technique with potential applications in measuring brain tumor perfusion, but its clinical impact remains to be determined. We assessed the usefulness of IVIM-metrics in predicting survival in newly diagnosed glioblastoma.Fifteen patients with glioblastoma underwent MRI including spin-echo echo-planar DWI using 13 b-values ranging from 0 to 1000 s/mm2. Parametric maps for diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) were generated for contrast-enhancing regions (CER) and non-enhancing regions (NCER). Regions of interest were manually drawn in regions of maximum f and on the corresponding dynamic susceptibility contrast images. Prognostic factors were evaluated by Kaplan-Meier survival and Cox proportional hazards analyses.We found that fCER and D*CER correlated with rCBFCER. The best cutoffs for 6-month survival were fCER>9.86% and D*CER>21.712 x10-3mm2/s (100% sensitivity, 71.4% specificity, 100% and 80% positive predictive values, and 80% and 100% negative predictive values; AUC:0.893 and 0.857, respectively). Treatment yielded the highest hazard ratio (5.484; 95% CI: 1.162-25.88; AUC: 0.723; P = 0.031); fCER combined with treatment predicted survival with 100% accuracy.The IVIM-metrics fCER and D*CER are promising biomarkers of 6-month survival in newly diagnosed glioblastoma.

SUBMITTER: Puig J 

PROVIDER: S-EPMC4936699 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objective</h4>Intravoxel incoherent motion (IVIM) is an MRI technique with potential applications in measuring brain tumor perfusion, but its clinical impact remains to be determined. We assessed the usefulness of IVIM-metrics in predicting survival in newly diagnosed glioblastoma.<h4>Methods</h4>Fifteen patients with glioblastoma underwent MRI including spin-echo echo-planar DWI using 13 b-values ranging from 0 to 1000 s/mm2. Parametric maps for diffusion coefficient (D), pseudodiffusion co  ...[more]

Similar Datasets

| S-EPMC8391260 | biostudies-literature
| S-EPMC7937866 | biostudies-literature
| S-EPMC3883504 | biostudies-other
| S-EPMC8186561 | biostudies-literature
| S-EPMC6364995 | biostudies-literature
| S-EPMC4731200 | biostudies-literature
| S-EPMC5412931 | biostudies-literature
| S-EPMC6886883 | biostudies-literature
| S-EPMC3758329 | biostudies-literature
| S-EPMC4315413 | biostudies-literature