Unknown

Dataset Information

0

Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable-Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization: 2-Year Results of the BIOSCIENCE Trial.


ABSTRACT: BACKGROUND:No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS:A total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP-SES (n=1063) or DP-EES (n=1056). Follow-up at 2 years was available for 2048 patients (97%). The primary end point was target-lesion failure, a composite of cardiac death, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. At 2 years, target-lesion failure occurred in 107 patients (10.5%) in the BP-SES arm and 107 patients (10.4%) in the DP-EES arm (risk ratio [RR] 1.00, 95% CI 0.77-1.31, P=0.979). There were no significant differences between BP-SES and DP-EES with respect to cardiac death (RR 1.01, 95% CI 0.62-1.63, P=0.984), target-vessel myocardial infarction (RR 0.91, 95% CI 0.60-1.39, P=0.669), target-lesion revascularization (RR 1.17, 95% CI 0.81-1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56-3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP-SES arm and 4 cases (0.4%) in the DP-EES arm (P=0.423). In the prespecified subgroup of patients with ST-segment elevation myocardial infarction, BP-SES was associated with a lower risk of target-lesion failure compared with DP-EES (RR 0.48, 95% CI 0.23-0.99, P=0.043, Pinteraction=0.026). CONCLUSIONS:Comparable safety and efficacy profiles of BP-SES and DP-EES were maintained throughout 2 years of follow-up. CLINICAL TRIAL REGISTRATION:URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.

SUBMITTER: Zbinden R 

PROVIDER: S-EPMC4943287 | biostudies-literature | 2016 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable-Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization: 2-Year Results of the BIOSCIENCE Trial.

Zbinden Rainer R   Piccolo Raffaele R   Heg Dik D   Roffi Marco M   Kurz David J DJ   Muller Olivier O   Vuilliomenet André A   Cook Stéphane S   Weilenmann Daniel D   Kaiser Christoph C   Jamshidi Peiman P   Franzone Anna A   Eberli Franz F   Jüni Peter P   Windecker Stephan S   Pilgrim Thomas T  

Journal of the American Heart Association 20160315 3


<h4>Background</h4>No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention.  ...[more]

Similar Datasets

| S-EPMC7531093 | biostudies-literature
| S-EPMC6898363 | biostudies-literature
| S-EPMC7552849 | biostudies-literature
| S-EPMC5975354 | biostudies-literature
| S-EPMC9292184 | biostudies-literature
| S-EPMC6797413 | biostudies-literature
| S-EPMC6915288 | biostudies-literature
| S-EPMC9904377 | biostudies-literature
| S-EPMC7067606 | biostudies-literature