Unknown

Dataset Information

0

Wide-Band Spatially Tunable Photonic Bandgap in Visible Spectral Range and Laser based on a Polymer Stabilized Blue Phase.


ABSTRACT: This work successfully develops a largely-gradient-pitched polymer-stabilized blue phase (PSBP) photonic bandgap (PBG) device with a wide-band spatial tunability in nearly entire visible region within a wide blue phase (BP) temperature range including room temperature. The device is fabricated based on the reverse diffusion of two injected BP-monomer mixtures with a low and a high chiral concentrations and afterwards through UV-curing. This gradient-pitched PSBP can show a rainbow-like reflection appearance in which the peak wavelength of the PBG can be spatially tuned from the blue to the red regions at room temperature. The total tuning spectral range for the cell is as broad as 165?nm and covers almost the entire visible region. Based on the gradient-pitched PSBP, a spatially tunable laser is also demonstrated in this work. The temperature sensitivity of the lasing wavelength for the laser is negatively linear and approximately -0.26?nm/°C. The two devices have a great potential for use in applications of photonic devices and displays because of their multiple advantages, such as wide-band tunability, wide operated temperature range, high stability and reliability, no issue of hysteresis, no need of external controlling sources, and not slow tuning speed (mechanically).

SUBMITTER: Lin JD 

PROVIDER: S-EPMC4960656 | biostudies-literature | 2016 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Wide-Band Spatially Tunable Photonic Bandgap in Visible Spectral Range and Laser based on a Polymer Stabilized Blue Phase.

Lin Jia-De JD   Wang Tsai-Yen TY   Mo Ting-Shan TS   Huang Shuan-Yu SY   Lee Chia-Rong CR  

Scientific reports 20160726


This work successfully develops a largely-gradient-pitched polymer-stabilized blue phase (PSBP) photonic bandgap (PBG) device with a wide-band spatial tunability in nearly entire visible region within a wide blue phase (BP) temperature range including room temperature. The device is fabricated based on the reverse diffusion of two injected BP-monomer mixtures with a low and a high chiral concentrations and afterwards through UV-curing. This gradient-pitched PSBP can show a rainbow-like reflectio  ...[more]

Similar Datasets

| S-EPMC8333255 | biostudies-literature
| S-EPMC6155245 | biostudies-literature
| S-EPMC6089888 | biostudies-other
| S-EPMC4932597 | biostudies-literature
| S-EPMC4780036 | biostudies-literature
| S-EPMC7770748 | biostudies-literature
| S-EPMC6615932 | biostudies-literature
| S-EPMC10574206 | biostudies-literature
| S-EPMC4845026 | biostudies-literature
| S-EPMC5040951 | biostudies-literature