Unknown

Dataset Information

0

Dual-Polymer Drops, Contact Lens Comfort, and Lid Wiper Epitheliopathy.


ABSTRACT: This study compared a new contact lens rewetting drop containing both carboxymethylcellulose and hyaluronic acid (CMC-HA) with a standard drop containing carboxymethylcellulose only (CMC). Symptoms of discomfort typical in lens wear and lid wiper epitheliopathy (LWE) were assessed over a 3-month period in a diverse sample of contact lens wearers.Adapted daily-wear contact lens subjects using hydrogel, silicone hydrogel, or rigid gas permeable lenses were enrolled in this prospective, randomized, double-masked, parallel-group, 90-day study conducted at 15 clinical sites. Subjects were randomized 2:1 to CMC-HA (n = 244) or CMC alone (n = 121) with dosage at least four times per day, along with their habitual lens care system. At baseline and at days 7, 30, 60, and 90, subject-completed questionnaires, bulbar conjunctival staining, LWE, contact lens distance visual acuity (CLDVA), and standard safety measures were assessed.At day 90, CMC-HA performed significantly better than CMC in ocular symptoms including dryness throughout the day (p = 0.006), and burning/stinging throughout the day (p = 0.02) and at the end of the day (p < 0.001). CMC-HA also performed numerically better for dryness at the end of day (p = 0.06). LWE staining was improved in the CMC-HA group at day 90 whereas it increased slightly in the CMC alone group, with a significant between-group difference (p = 0.009). CMC-HA also demonstrated greater reduction in conjunctival staining compared with CMC alone at day 90 (p = 0.08). No differences in CLDVA, contact lens wear time, acceptability, and product use were observed, and safety outcomes were similar between groups.The addition of HA to a standard CMC rewetting drop improves clinical performance. In this comparison of rewetting drop efficacy in contact lens wearers, LWE was a useful clinical sign for differentiating clinical performance.

SUBMITTER: Nichols JJ 

PROVIDER: S-EPMC4972480 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dual-Polymer Drops, Contact Lens Comfort, and Lid Wiper Epitheliopathy.

Nichols Jason J JJ   Lievens Christopher W CW   Bloomenstein Marc R MR   Liu Haixia H   Simmons Peter P   Vehige Joseph J  

Optometry and vision science : official publication of the American Academy of Optometry 20160801 8


<h4>Purpose</h4>This study compared a new contact lens rewetting drop containing both carboxymethylcellulose and hyaluronic acid (CMC-HA) with a standard drop containing carboxymethylcellulose only (CMC). Symptoms of discomfort typical in lens wear and lid wiper epitheliopathy (LWE) were assessed over a 3-month period in a diverse sample of contact lens wearers.<h4>Methods</h4>Adapted daily-wear contact lens subjects using hydrogel, silicone hydrogel, or rigid gas permeable lenses were enrolled  ...[more]

Similar Datasets

| S-EPMC5072130 | biostudies-literature
| S-EPMC4533967 | biostudies-literature
| S-EPMC5025225 | biostudies-literature
| S-EPMC4113198 | biostudies-literature
| S-EPMC7447315 | biostudies-literature
| S-EPMC6219638 | biostudies-literature
| S-EPMC7525312 | biostudies-literature
| S-EPMC3835900 | biostudies-literature
| S-EPMC6356913 | biostudies-literature
| S-EPMC7481179 | biostudies-literature