Unknown

Dataset Information

0

Revisiting Mitochondrial pH with an Improved Algorithm for Calibration of the Ratiometric 5(6)-carboxy-SNARF-1 Probe Reveals Anticooperative Reaction with H+ Ions and Warrants Further Studies of Organellar pH.


ABSTRACT: Fluorescence measurements of pH and other analytes in the cell rely on accurate calibrations, but these have routinely used algorithms that inadequately describe the properties of indicators. Here, we have established a more accurate method for calibrating and analyzing data obtained using the ratiometric probe 5(6)-carboxy-SNARF-1. We tested the implications of novel approach to measurements of pH in yeast mitochondria, a compartment containing a small number of free H+ ions. Our findings demonstrate that 5(6)-carboxy-SNARF-1 interacts with H+ ions inside the mitochondria in an anticooperative manner (Hill coefficient n of 0.5) and the apparent pH inside the mitochondria is ~0.5 unit lower than had been generally assumed. This result, at odds with the current consensus on the mechanism of energy generation in the mitochondria, is in better agreement with theoretical considerations and warrants further studies of organellar pH.

SUBMITTER: Zurawik TM 

PROVIDER: S-EPMC4996429 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Revisiting Mitochondrial pH with an Improved Algorithm for Calibration of the Ratiometric 5(6)-carboxy-SNARF-1 Probe Reveals Anticooperative Reaction with H+ Ions and Warrants Further Studies of Organellar pH.

Żurawik Tomasz Michał TM   Pomorski Adam A   Belczyk-Ciesielska Agnieszka A   Goch Grażyna G   Niedźwiedzka Katarzyna K   Kucharczyk Róża R   Krężel Artur A   Bal Wojciech W  

PloS one 20160824 8


Fluorescence measurements of pH and other analytes in the cell rely on accurate calibrations, but these have routinely used algorithms that inadequately describe the properties of indicators. Here, we have established a more accurate method for calibrating and analyzing data obtained using the ratiometric probe 5(6)-carboxy-SNARF-1. We tested the implications of novel approach to measurements of pH in yeast mitochondria, a compartment containing a small number of free H+ ions. Our findings demon  ...[more]

Similar Datasets

| S-EPMC4309718 | biostudies-literature
| S-EPMC5101900 | biostudies-literature
| S-EPMC6978660 | biostudies-literature
| S-EPMC387601 | biostudies-literature
| S-EPMC4582792 | biostudies-literature
| S-EPMC5999021 | biostudies-literature
| S-EPMC5049506 | biostudies-literature
| S-EPMC7107693 | biostudies-literature
| S-EPMC5603529 | biostudies-literature
| S-EPMC6742514 | biostudies-literature