US-SOMO HPLC-SAXS module: dealing with capillary fouling and extraction of pure component patterns from poorly resolved SEC-SAXS data.


ABSTRACT: Size-exclusion chromatography coupled with SAXS (small-angle X-ray scattering), often performed using a flow-through capillary, should allow direct collection of monodisperse sample data. However, capillary fouling issues and non-baseline-resolved peaks can hamper its efficacy. The UltraScan solution modeler (US-SOMO) HPLC-SAXS (high-performance liquid chromatography coupled with SAXS) module provides a comprehensive framework to analyze such data, starting with a simple linear baseline correction and symmetrical Gaussian decomposition tools [Brookes, Pérez, Cardinali, Profumo, Vachette & Rocco (2013 ?). J. Appl. Cryst.46, 1823-1833]. In addition to several new features, substantial improvements to both routines have now been implemented, comprising the evaluation of outcomes by advanced statistical tools. The novel integral baseline-correction procedure is based on the more sound assumption that the effect of capillary fouling on scattering increases monotonically with the intensity scattered by the material within the X-ray beam. Overlapping peaks, often skewed because of sample interaction with the column matrix, can now be accurately decomposed using non-symmetrical modified Gaussian functions. As an example, the case of a polydisperse solution of aldolase is analyzed: from heavily convoluted peaks, individual SAXS profiles of tetramers, octamers and dodecamers are extracted and reliably modeled.

SUBMITTER: Brookes E 

PROVIDER: S-EPMC5045733 | biostudies-literature | 2016 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

<i>US-SOMO</i> HPLC-SAXS module: dealing with capillary fouling and extraction of pure component patterns from poorly resolved SEC-SAXS data.

Brookes Emre E   Vachette Patrice P   Rocco Mattia M   Pérez Javier J  

Journal of applied crystallography 20160901 Pt 5


Size-exclusion chromatography coupled with SAXS (small-angle X-ray scattering), often performed using a flow-through capillary, should allow direct collection of monodisperse sample data. However, capillary fouling issues and non-baseline-resolved peaks can hamper its efficacy. The <i>UltraScan</i> solution modeler (<i>US-SOMO</i>) HPLC-SAXS (high-performance liquid chromatography coupled with SAXS) module provides a comprehensive framework to analyze such data, starting with a simple linear bas  ...[more]

Similar Datasets

| S-EPMC3831300 | biostudies-literature
| S-EPMC3351611 | biostudies-literature
| S-EPMC4304689 | biostudies-literature
| S-EPMC1221013 | biostudies-other
| S-EPMC6529771 | biostudies-literature
| S-EPMC5219594 | biostudies-literature
| PRJNA983560 | ENA
| S-EPMC6816929 | biostudies-literature
| S-EPMC2880463 | biostudies-literature
| S-EPMC4326712 | biostudies-literature