Unknown

Dataset Information

0

High-resolution 3D volumetry versus conventional measuring techniques for the assessment of experimental lymphedema in the mouse hindlimb.


ABSTRACT: Secondary lymphedema is a common complication of cancer treatment characterized by chronic limb swelling with interstitial inflammation. The rodent hindlimb is a widely used model for the evaluation of novel lymphedema treatments. However, the assessment of limb volume in small animals is challenging. Recently, high-resolution three-dimensional (3D) imaging modalities have been introduced for rodent limb volumetry. In the present study we evaluated the validity of microcomputed tomography (?CT), magnetic resonance imaging (MRI) and ultrasound in comparison to conventional measuring techniques. For this purpose, acute lymphedema was induced in the mouse hindlimb by a modified popliteal lymphadenectomy. The 4-week course of this type of lymphedema was first assessed in 6 animals. In additional 12 animals, limb volumes were analyzed by ?CT, 9.4 T MRI and 30?MHz ultrasound as well as by planimetry, circumferential length and paw thickness measurements. Interobserver correlation was high for all modalities, in particular for ?CT analysis (r?=?0.975, p?

SUBMITTER: Frueh FS 

PROVIDER: S-EPMC5048170 | biostudies-literature | 2016 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-resolution 3D volumetry versus conventional measuring techniques for the assessment of experimental lymphedema in the mouse hindlimb.

Frueh Florian S FS   Körbel Christina C   Gassert Laura L   Müller Andreas A   Gousopoulos Epameinondas E   Lindenblatt Nicole N   Giovanoli Pietro P   Laschke Matthias W MW   Menger Michael D MD  

Scientific reports 20161004


Secondary lymphedema is a common complication of cancer treatment characterized by chronic limb swelling with interstitial inflammation. The rodent hindlimb is a widely used model for the evaluation of novel lymphedema treatments. However, the assessment of limb volume in small animals is challenging. Recently, high-resolution three-dimensional (3D) imaging modalities have been introduced for rodent limb volumetry. In the present study we evaluated the validity of microcomputed tomography (μCT),  ...[more]

Similar Datasets

| S-EPMC3856125 | biostudies-literature
| S-EPMC9293915 | biostudies-literature
| S-EPMC3543368 | biostudies-other
| S-EPMC9997642 | biostudies-literature
| S-EPMC6719308 | biostudies-literature
| S-EPMC3586703 | biostudies-other
| S-EPMC3644654 | biostudies-literature
2010-05-26 | GSE16359 | GEO
| S-EPMC4561513 | biostudies-literature