Unknown

Dataset Information

0

Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches.


ABSTRACT:

Objectives

(1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics.

Methods

Thirty-three adults [mean age (standard deviation (SD)) = 27.4 (5.9) years; mean BMI (SD) = 23.9 (3.7) kg/m2; 20 females (60.6%)] wore four accelerometers; an ActiGraph GT3X+ and a GENEActiv on the right hip; and an ActiGraph GT3X+ and a GENEActiv on the non-dominant wrist. Under laboratory-conditions, participants performed 16 different activities (11 sedentary behaviours and 5 light-intensity physical activities) for 5 minutes each. ENMO and MAD were computed from the raw acceleration data, and logistic regression and receiver-operating-characteristic (ROC) analyses were implemented to derive thresholds for activity discrimination. Areas under ROC curves (AUROC) were calculated to summarise performances and thresholds were assessed via executing leave-one-out-cross-validations.

Results

For both hip and wrist monitor placements, in comparison to the ActiGraph GT3X+ monitors, the ENMO and MAD values derived from the GENEActiv devices were observed to be slightly higher, particularly for the lower-intensity activities. Monitor-specific hip and wrist ENMO and MAD thresholds showed excellent ability for separating sedentary behaviours from motion-based light-intensity physical activities (in general, AUROCs >0.95), with validation indicating robustness. However, poor classification was experienced when attempting to isolate standing still from sedentary behaviours (in general, AUROCs <0.65). The ENMO and MAD metrics tended to perform similarly across activities and accelerometer brands.

Conclusions

Researchers can utilise these robust monitor-specific hip and wrist ENMO and MAD thresholds, in order to accurately separate sedentary behaviours from common motion-based light-intensity physical activities. However, caution should be taken if isolating sedentary behaviours from standing is of particular interest.

SUBMITTER: Bakrania K 

PROVIDER: S-EPMC5051724 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches.

Bakrania Kishan K   Yates Thomas T   Rowlands Alex V AV   Esliger Dale W DW   Bunnewell Sarah S   Sanders James J   Davies Melanie M   Khunti Kamlesh K   Edwardson Charlotte L CL  

PloS one 20161005 10


<h4>Objectives</h4>(1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics.<h4>Methods</h4>Thirty-three adults [mean age (standard deviation (SD)) = 27.4 (5.9) years; mean BMI (SD  ...[more]

Similar Datasets

| S-EPMC4546343 | biostudies-literature
| S-EPMC7560095 | biostudies-literature
| S-EPMC6306859 | biostudies-literature
| S-EPMC5587915 | biostudies-literature
| S-EPMC10015464 | biostudies-literature
| S-EPMC3324767 | biostudies-literature
| S-EPMC7446919 | biostudies-literature
| S-EPMC2830444 | biostudies-literature
| S-EPMC6405451 | biostudies-literature
| S-EPMC7390706 | biostudies-literature