Unknown

Dataset Information

0

Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution.


ABSTRACT: PURPOSE:This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA sorbed from Biotrue, an HA-containing multipurpose solution (MPS), onto senofilcon A lenses affects the concentration of HA in tears after 2 hours of wear. PATIENTS AND METHODS:Tears of habitual CL wearers and non-CL wearers were collected on Schirmer strips at baseline and after 2 hours of wear of senofilcon A CLs that had first been either rinsed with Sensitive Eyes Saline or soaked in Biotrue MPS for 14 hours. HA concentrations were measured by enzyme-linked immunosorbent assay (ELISA) and adjusted for sample volumes. RESULTS:No difference in baseline concentrations of HA in tears was found between CL wearers and non-CL wearers (P=0.07), nor between males and females (P=0.06). However, age was significantly negatively associated with HA concentration (P<0.01), and mostly, CL wear contributed to a significant association (P<0.01). Among saline-rinsed CL wearers, no change in HA concentration in tears was observed after 2 hours of wear (P=0.38). By contrast, a significant increase in HA concentration was observed in the tears from eyes that had worn CLs soaked in Biotrue MPS when compared to baseline (P=0.01) or to saline-rinsed control (P=0.03). CONCLUSION:1) In this study population, no difference in baseline concentration of HA was observed between CL wearers and non-CL wearers, and 2) after 2 hours of wear of senofilcon A lenses that were soaked in Biotrue MPS, HA concentrations in the tear films of CL wearers increased.

SUBMITTER: Scheuer CA 

PROVIDER: S-EPMC5063495 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Increased concentration of hyaluronan in tears after soaking contact lenses in Biotrue multipurpose solution.

Scheuer Catherine A CA   Rah Marjorie J MJ   Reindel William T WT  

Clinical ophthalmology (Auckland, N.Z.) 20161007


<h4>Purpose</h4>This study was conducted to determine 1) the concentration of hyaluronan (HA) in the tear films of contact lens (CL) wearers versus non-CL wearers and 2) whether HA sorbed from Biotrue, an HA-containing multipurpose solution (MPS), onto senofilcon A lenses affects the concentration of HA in tears after 2 hours of wear.<h4>Patients and methods</h4>Tears of habitual CL wearers and non-CL wearers were collected on Schirmer strips at baseline and after 2 hours of wear of senofilcon A  ...[more]

Similar Datasets

| S-EPMC4314626 | biostudies-literature
| S-EPMC7320721 | biostudies-literature
| S-EPMC6607692 | biostudies-literature
| S-EPMC8396802 | biostudies-literature
| S-EPMC6691754 | biostudies-literature
| S-EPMC6070515 | biostudies-literature
| S-EPMC5530011 | biostudies-other
2022-11-07 | PXD029188 | Pride
| S-EPMC6175897 | biostudies-other
| S-EPMC3208141 | biostudies-literature