Saturation monitoring of VX15/2503, a novel semaphorin 4D-specific antibody, in clinical trials.


ABSTRACT: BACKGROUND:Receptor occupancy, or saturation, assays are often utilized in preclinical and clinical development programs to evaluate the binding of a biologic to a cellular target. These assays provide critical information regarding the dose of drug required to "saturate" the target as well as important pharmacodymamic (PD) data. A flow cytometric method was developed to measure the degree of Semaphorin 4D (SEMA4D; CD100) saturation by VX15/2303, an investigational monoclonal antibody specific for SEMA4D. METHODS:The assay detects VX15/2503, a human IgG4 specific for SEMA4D, with an IgG4 -specific monoclonal antibody. RESULTS:Data generated allowed assessment of two related SEMA4D-specific pharmacodynamic (PD) markers: (1) The measurement of cellular SEMA4D (cSEMA4D) saturation by VX15/2503, and (2) the cell membrane expression levels of cSEMA4D. CONCLUSIONS:This assay specifically and reproducibly measured cSEMA4D saturation and expression levels. Evaluation of the SEMA4D-specific PD markers were critical in determining the clinical saturation threshold of cSEMA4D by VX15/2503.

SUBMITTER: Fisher TL 

PROVIDER: S-EPMC5064733 | biostudies-literature | 2016 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Saturation monitoring of VX15/2503, a novel semaphorin 4D-specific antibody, in clinical trials.

Fisher Terrence L TL   Seils Jennifer J   Reilly Christine C   Litwin Virginia V   Green Lisa L   Salkowitz-Bokal Janelle J   Walsh Robin R   Harville Sarah S   Leonard John E JE   Smith Ernest E   Zauderer Maurice M  

Cytometry. Part B, Clinical cytometry 20151224 2


<h4>Background</h4>Receptor occupancy, or saturation, assays are often utilized in preclinical and clinical development programs to evaluate the binding of a biologic to a cellular target. These assays provide critical information regarding the dose of drug required to "saturate" the target as well as important pharmacodymamic (PD) data. A flow cytometric method was developed to measure the degree of Semaphorin 4D (SEMA4D; CD100) saturation by VX15/2303, an investigational monoclonal antibody sp  ...[more]

Similar Datasets

| S-EPMC7611261 | biostudies-literature
| S-EPMC5473956 | biostudies-literature
| S-EPMC4026538 | biostudies-literature
| S-EPMC10240960 | biostudies-literature
| S-EPMC6400819 | biostudies-literature
| S-EPMC5990477 | biostudies-literature
| S-EPMC3585808 | biostudies-literature
| S-EPMC1408676 | biostudies-other
| S-EPMC4635900 | biostudies-other
| S-EPMC3202567 | biostudies-literature