ABSTRACT: Objective
The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of both tests in patients admitted to an acute stroke unit.Methods
Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% a