Blood Glucose Levels of Subelite Athletes During 6 Days of Free Living.


ABSTRACT:

Background

Continuous glucose monitoring (CGM) devices, with their 1-5 min measurement interval, allow blood glucose (BG) concentration dynamics to be captured more frequently and less invasively than traditional BG measures. One cohort CGM could provide insight is athletes. This study investigates what impact their heightened energy expenditure and dietary intake may have on their ability to achieve optimal BG.

Methods

Ten subelite athletes (resting HR<60 bpm, training>6 hrs per week) were recruited. Two Ipro2 CGM devices (Medtronic Minimed, Northridge, CA) were inserted into the abdomen and remained in place for ~6 days. Time in band was calculated as the percentage of CGM BG measurements with in the 4.0-6.0 mmol/L. Fasting glucose was calculated using CGM calibration BG measurements and postprandial glucose response was also calculated using the CGM values.

Results

4/10 athletes studied spent more than 70% of the total monitoring time above 6.0 mmol/L even with the 2-hour period after meals is excluded. Fasting BG was also in the ADA defined prediabetes range for 3/10 athletes. Only 1 participant spent substantial time below 4.0 mmol/L which was largely due to significantly lower energy intake compared to recommendations.

Conclusions

Contrary to expectations high BG appears to be more of a concern for athletes then low BG even in those with the highest energy expenditure and consuming below the recommended carbohydrate intake. This study warrants further investigation on the recommended diets and the BG of athletes to better determine the causes and impact of this hyperglycemia on overall athlete health.

SUBMITTER: Thomas F 

PROVIDER: S-EPMC5094325 | biostudies-literature | 2016 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Blood Glucose Levels of Subelite Athletes During 6 Days of Free Living.

Thomas Felicity F   Pretty Chris G CG   Desaive Thomas T   Chase J Geoffrey JG  

Journal of diabetes science and technology 20161101 6


<h4>Background</h4>Continuous glucose monitoring (CGM) devices, with their 1-5 min measurement interval, allow blood glucose (BG) concentration dynamics to be captured more frequently and less invasively than traditional BG measures. One cohort CGM could provide insight is athletes. This study investigates what impact their heightened energy expenditure and dietary intake may have on their ability to achieve optimal BG.<h4>Methods</h4>Ten subelite athletes (resting HR<60 bpm, training>6 hrs per  ...[more]

Similar Datasets

| S-EPMC4724204 | biostudies-other
| S-EPMC4649721 | biostudies-literature
| S-EPMC4455746 | biostudies-literature
| S-EPMC8187578 | biostudies-literature
| S-EPMC6468119 | biostudies-literature
| S-EPMC6432689 | biostudies-literature
| S-EPMC5431098 | biostudies-literature
2021-10-11 | PXD029066 |
2019-12-31 | GSE122671 | GEO
2004-10-21 | GSE1322 | GEO