Unknown

Dataset Information

0

Magnetic resonance and ultrasound contrast imaging of polymer-shelled microbubbles loaded with iron oxide nanoparticles.


ABSTRACT: Dual-mode contrast agents (CAs) have great potential for improving diagnostics. However, the effectiveness of CAs is strictly related to both the solution adopted to merge the two agents into a single probe unit, and the ratio between the two agents. In this study, two dual-mode CAs for simultaneous magnetic resonance imaging (MRI) and ultrasound imaging (UI) were assessed. For this purpose, different densities of superparamagnetic iron oxide nanoparticles (SPIONs) were anchored to the external surface of polymer-shelled microbubbles (MBs) or were physically entrapped into the shell. In vitro static and dynamic experiments were carried out with a limited concentration of modified MBs (106?bubbles?ml-1) by avoiding destruction during UI (performed at a peak pressure lower than 320?kPa) and by using a low-field MRI system (with a magnetic flux density equal to 0.25?T). Under these conditions, different imaging techniques, set-up parameters and SPION densities were used to achieve satisfactory detection of the CAs by using both UI and MRI. However, when the SPION density was increased, the MRI contrast improved, whereas the UI contrast worsened due to the reduced elasticity of the MB shell. For both UI and MRI, MBs with externally anchored SPIONs provided better performance than MBs with SPIONs entrapped into the shell. In particular, a SPION density of 29% with respect to the mass of the MBs was successfully tested.

SUBMITTER: Sciallero C 

PROVIDER: S-EPMC5108937 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Magnetic resonance and ultrasound contrast imaging of polymer-shelled microbubbles loaded with iron oxide nanoparticles.

Sciallero Claudia C   Balbi Luca L   Paradossi Gaio G   Trucco Andrea A  

Royal Society open science 20160803 8


Dual-mode contrast agents (CAs) have great potential for improving diagnostics. However, the effectiveness of CAs is strictly related to both the solution adopted to merge the two agents into a single probe unit, and the ratio between the two agents. In this study, two dual-mode CAs for simultaneous magnetic resonance imaging (MRI) and ultrasound imaging (UI) were assessed. For this purpose, different densities of superparamagnetic iron oxide nanoparticles (SPIONs) were anchored to the external  ...[more]

Similar Datasets

| S-EPMC3601761 | biostudies-literature
| S-EPMC4228079 | biostudies-literature
| S-EPMC3094458 | biostudies-other
| S-EPMC9057352 | biostudies-literature
| S-EPMC4251562 | biostudies-literature
| S-EPMC9798828 | biostudies-literature
| S-EPMC9988694 | biostudies-literature
| S-EPMC5645056 | biostudies-literature
| S-EPMC9416939 | biostudies-literature
| S-EPMC7367688 | biostudies-literature