How Accurate Is the Prediction of Maximal Oxygen Uptake with Treadmill Testing?


ABSTRACT:

Background

Cardiorespiratory fitness measured by treadmill testing has prognostic significance in determining mortality with cardiovascular and other chronic disease states. The accuracy of a recently developed method for estimating maximal oxygen uptake (VO2peak), the heart rate index (HRI), is dependent only on heart rate (HR) and was tested against oxygen uptake (VO2), either measured or predicted from conventional treadmill parameters (speed, incline, protocol time).

Methods

The HRI equation, METs = 6 x HRI- 5, where HRI = maximal HR/resting HR, provides a surrogate measure of VO2peak. Forty large scale treadmill studies were identified through a systematic search using MEDLINE, Google Scholar and Web of Science in which VO2peak was either measured (TM-VO2meas; n = 20) or predicted (TM-VO2pred; n = 20) based on treadmill parameters. All studies were required to have reported group mean data of both resting and maximal HRs for determination of HR index-derived oxygen uptake (HRI-VO2).

Results

The 20 studies with measured VO2 (TM-VO2meas), involved 11,477 participants (median 337) with a total of 105,044 participants (median 3,736) in the 20 studies with predicted VO2 (TM-VO2pred). A difference of only 0.4% was seen between mean (±SD) VO2peak for TM- VO2meas and HRI-VO2 (6.51±2.25 METs and 6.54±2.28, respectively; p = 0.84). In contrast, there was a highly significant 21.1% difference between mean (±SD) TM-VO2pred and HRI-VO2 (8.12±1.85 METs and 6.71±1.92, respectively; p<0.001).

Conclusion

Although mean TM-VO2meas and HRI-VO2 were almost identical, mean TM-VO2pred was more than 20% greater than mean HRI-VO2.

SUBMITTER: Wicks JR 

PROVIDER: S-EPMC5119771 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

How Accurate Is the Prediction of Maximal Oxygen Uptake with Treadmill Testing?

Wicks John R JR   Oldridge Neil B NB  

PloS one 20161122 11


<h4>Background</h4>Cardiorespiratory fitness measured by treadmill testing has prognostic significance in determining mortality with cardiovascular and other chronic disease states. The accuracy of a recently developed method for estimating maximal oxygen uptake (VO2peak), the heart rate index (HRI), is dependent only on heart rate (HR) and was tested against oxygen uptake (VO2), either measured or predicted from conventional treadmill parameters (speed, incline, protocol time).<h4>Methods</h4>T  ...[more]

Similar Datasets

| S-EPMC3027125 | biostudies-literature
| S-EPMC8100405 | biostudies-literature
| S-EPMC7540168 | biostudies-literature
| S-EPMC8120347 | biostudies-literature
| S-EPMC8452225 | biostudies-literature
| S-EPMC5721097 | biostudies-literature
| S-EPMC11348524 | biostudies-literature
| S-EPMC7971079 | biostudies-literature
| S-EPMC5330462 | biostudies-literature
| S-EPMC7835615 | biostudies-literature