Unknown

Dataset Information

0

A Dual Filtration-Based Multiplex PCR Method for Simultaneous Detection of Viable Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus on Fresh-Cut Cantaloupe.


ABSTRACT: Fresh-cut cantaloupe is particularly susceptible to contamination with pathogenic bacteria, such as Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus. Therefore, development of rapid, yet accurate detection techniques is necessary to ensure food safety. In this study, a multiplex PCR system and propidium monoazide (PMA) concentration were optimized to detect all viable pathogens in a single tube. A dual filtration system utilized a filtration membrane with different pore sizes to enrich pathogens found on fresh-cut cantaloupe. The results revealed that an optimized multiplex PCR system has the ability to effectively detect three pathogens in the same tube. The viable pathogens were simultaneously detected for PMA concentrations above 10 ?g/ml. The combination of a nylon membrane (15 ?m) and a micro pore filtration membrane (0.22 ?m) formed the dual filtration system used to enrich pathogens. The achieved sensitivity of PMA-mPCR based on this dual filtration system was 2.6 × 103 cfu/g for L. monocytogenes, 4.3 × 10 cfu/g for E. coli O157:H7, and 3.1 × 102 cfu/g for S. aureus. Fresh-cut cantaloupe was inoculated with the three target pathogens using concentrations of 103, 102, 10, and 1 cfu/g. After 6-h of enrichment culture, assay sensitivity increased to 1 cfu/g for each of these pathogens. Thus, this technique represents an efficient and rapid detection tool for implementation on fresh-cut cantaloupe.

SUBMITTER: Feng K 

PROVIDER: S-EPMC5132219 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Dual Filtration-Based Multiplex PCR Method for Simultaneous Detection of Viable Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus on Fresh-Cut Cantaloupe.

Feng Ke K   Hu Wenzhong W   Jiang Aili A   Sarengaowa   Xu Yongping Y   Zou Yu Y   Yang Liu L   Wang Xin X  

PloS one 20161201 12


Fresh-cut cantaloupe is particularly susceptible to contamination with pathogenic bacteria, such as Escherichia coli O157:H7, Listeria monocytogenes, and Staphylococcus aureus. Therefore, development of rapid, yet accurate detection techniques is necessary to ensure food safety. In this study, a multiplex PCR system and propidium monoazide (PMA) concentration were optimized to detect all viable pathogens in a single tube. A dual filtration system utilized a filtration membrane with different por  ...[more]

Similar Datasets

| S-EPMC4651082 | biostudies-literature
| S-EPMC4662235 | biostudies-literature
| S-EPMC7755191 | biostudies-literature
| S-EPMC10926056 | biostudies-literature
| S-EPMC7755251 | biostudies-literature
| S-EPMC2519329 | biostudies-literature
| S-EPMC91307 | biostudies-literature
| S-EPMC4829520 | biostudies-literature
| S-EPMC7554816 | biostudies-literature
| S-EPMC5522875 | biostudies-other