Unknown

Dataset Information

0

Over 4100 protein identifications from a Xenopus laevis fertilized egg digest using reversed-phase chromatographic prefractionation followed by capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry analysis.


ABSTRACT: A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by RPLC. One set of 30 fractions was analyzed by 100-min CZE-ESI-MS/MS separations (50 h total instrument time), and a second set of 15 fractions was analyzed by 3-h UPLC-ESI-MS/MS separations (45 h total instrument time). CZE-MS/MS produced 70% as many protein IDs (4134 versus 5787) and 60% as many peptide IDs (22?535 versus 36?848) as UPLC-MS/MS with similar instrument time (50 h versus 45 h) but with 50 times smaller total consumed sample amount (1.5 ?g versus 75 ?g). Surprisingly, CZE generated peaks that were 25% more intense than UPLC for peptides that were identified by both techniques, despite the 50-fold lower loading amount; this high sensitivity reflects the efficient ionization produced by the electrokinetically pumped nanospray interface used in CZE. This report is the first comparison of CZE-MS/MS and UPLC-MS/MS for large-scale eukaryotic proteomic analysis. The numbers of protein and peptide identifications produced by CZE-ESI-MS/MS approach those produced by UPLC-MS/MS, but with nearly two orders of magnitude lower sample amounts.

SUBMITTER: Yan X 

PROVIDER: S-EPMC5140748 | biostudies-literature | 2016 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Over 4100 protein identifications from a Xenopus laevis fertilized egg digest using reversed-phase chromatographic prefractionation followed by capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry analysis.

Yan Xiaojing X   Sun Liangliang L   Zhu Guijie G   Cox Olivia F OF   Dovichi Norman J NJ  

Proteomics 20161201 23


A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by RPLC. One set of 30 fractions was analyzed by 100-min CZE-ESI-MS/MS separations (50 h total instrument time), and a second set of 15 fractions was analyzed by 3-h UPLC-ESI-MS/MS separations (45 h total instrument time). CZE-MS/MS produced 70% as many protein IDs (4134 versus 5787) and 60% as many peptide IDs (22 535 versus 36 848) as UPLC-MS/MS with similar instrument time (50 h versus 45 h) but with 50 times s  ...[more]

Similar Datasets

| S-EPMC3594080 | biostudies-literature
| S-EPMC4763991 | biostudies-literature
| S-EPMC5581245 | biostudies-literature
| S-EPMC6156779 | biostudies-literature
| S-EPMC5771954 | biostudies-literature
| S-EPMC8671870 | biostudies-literature
| S-EPMC3670666 | biostudies-literature
| S-EPMC4470751 | biostudies-literature
| S-EPMC7695695 | biostudies-literature
| S-EPMC9850406 | biostudies-literature