Unknown

Dataset Information

0

Multi-Material Tissue Engineering Scaffold with Hierarchical Pore Architecture.


ABSTRACT: Multi-material polymer scaffolds with multiscale pore architectures were characterized and tested with vascular and heart cells as part of a platform for replacing damaged heart muscle. Vascular and muscle scaffolds were constructed from a new material, poly(limonene thioether) (PLT32i), which met the design criteria of slow biodegradability, elastomeric mechanical properties, and facile processing. The vascular-parenchymal interface was a poly(glycerol sebacate) (PGS) porous membrane that met different criteria of rapid biodegradability, high oxygen permeance, and high porosity. A hierarchical architecture of primary (macroscale) and secondary (microscale) pores was created by casting the PLT32i prepolymer onto sintered spheres of poly(methyl methacrylate) (PMMA) within precisely patterned molds followed by photocuring, de-molding, and leaching out the PMMA. Pre-fabricated polymer templates were cellularized, assembled, and perfused in order to engineer spatially organized, contractile heart tissue. Structural and functional analyses showed that the primary pores guided heart cell alignment and enabled robust perfusion while the secondary pores increased heart cell retention and reduced polymer volume fraction.

SUBMITTER: Morgan KY 

PROVIDER: S-EPMC5142531 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multi-Material Tissue Engineering Scaffold with Hierarchical Pore Architecture.

Morgan Kathy Ye KY   Sklaviadis Demetra D   Tochka Zachary L ZL   Fischer Kristin M KM   Hearon Keith K   Morgan Thomas D TD   Langer Robert R   Freed Lisa E LE  

Advanced functional materials 20160613 32


Multi-material polymer scaffolds with multiscale pore architectures were characterized and tested with vascular and heart cells as part of a platform for replacing damaged heart muscle. Vascular and muscle scaffolds were constructed from a new material, poly(limonene thioether) (PLT32i), which met the design criteria of slow biodegradability, elastomeric mechanical properties, and facile processing. The vascular-parenchymal interface was a poly(glycerol sebacate) (PGS) porous membrane that met d  ...[more]

Similar Datasets

| S-EPMC3938937 | biostudies-literature
| S-EPMC5682611 | biostudies-literature
| S-EPMC3292831 | biostudies-other
| S-EPMC3479404 | biostudies-literature
| S-EPMC5432418 | biostudies-literature
| S-EPMC4078891 | biostudies-literature
| S-EPMC3003664 | biostudies-literature
| S-EPMC5503070 | biostudies-other
| S-EPMC2748110 | biostudies-literature
| S-EPMC4828277 | biostudies-literature