Unknown

Dataset Information

0

Diffusion tensor imaging measures of white matter compared to myelin basic protein immunofluorescence in tissue cleared intact brains.


ABSTRACT: We provide datasets from combined ex vivo diffusion tensor imaging (DTI) and Clear Lipid-exchanged, Anatomically Rigid, Imaging/immunostaining compatible, Tissue hYdrogel (CLARITY) performed on intact mouse brains. DTI-derived measures of fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) were compared to antibody-based labeling of myelin basic protein (MBP), as measured by fluorescence microscopy. We used a customized CLARITY hydrogel solution to facilitate whole brain tissue clearing and subsequent immunolabeling. We describe how CLARITY was made compatible with magnetic resonance imaging with the intention of facilitating future multimodal imaging studies that may combine noninvasive imaging with 3D immunohistochemistry. These data and methods are related to the accompanying research article entitled, 'The role of myelination in measures of white matter integrity: Combination of diffusion tensor imaging and two-photon microscopy of CLARITY intact brains' (E.H. Chang, M. Argyelan, M. Aggarwal, T-S. Chandon, K.H. Karlsgodt, S. Mori, A.K. Malhotra, 2016) [1].

SUBMITTER: Chang EH 

PROVIDER: S-EPMC5198630 | biostudies-literature | 2017 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diffusion tensor imaging measures of white matter compared to myelin basic protein immunofluorescence in tissue cleared intact brains.

Chang Eric H EH   Argyelan Miklos M   Aggarwal Manisha M   Chandon Toni-Shay S TS   Karlsgodt Katherine H KH   Mori Susumu S   Malhotra Anil K AK  

Data in brief 20161218


We provide datasets from combined <i>ex vivo</i> diffusion tensor imaging (DTI) and Clear Lipid-exchanged, Anatomically Rigid, Imaging/immunostaining compatible, Tissue hYdrogel (CLARITY) performed on intact mouse brains. DTI-derived measures of fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) were compared to antibody-based labeling of myelin basic protein (MBP), as measured by fluorescence microscopy. We used a customized CLARITY hydrogel solution to facilitate w  ...[more]

Similar Datasets

| S-EPMC4439039 | biostudies-literature
| S-EPMC6384876 | biostudies-literature
| S-EPMC4482724 | biostudies-literature
| S-EPMC4528565 | biostudies-literature
| S-EPMC6124722 | biostudies-literature
| S-EPMC10749242 | biostudies-literature
| S-EPMC4906378 | biostudies-literature
| S-EPMC7425333 | biostudies-literature
| S-EPMC2808804 | biostudies-literature
| S-EPMC8006297 | biostudies-literature