Evaluating Physical Outcomes in Acute Respiratory Distress Syndrome Survivors: Validity, Responsiveness, and Minimal Important Difference of 4-Meter Gait Speed Test.


ABSTRACT: To examine the reliability, validity, responsiveness, and minimal important difference of the 4-m gait speed test in acute respiratory distress syndrome survivors.Secondary analyses of data from two longitudinal follow-up studies of acute respiratory distress syndrome survivors. Test-retest and inter-rater reliability, construct validity (convergent, discriminant, and known group), predictive validity, and responsiveness were examined. The minimal important difference was estimated using anchor- and distribution-based approaches.A national multicenter prospective study (ARDSNet Long-Term Outcome Study) and a multisite prospective study in Baltimore, MD (Improving Care of Acute Lung Injury Patients).Acute respiratory distress syndrome survivors with 4-m gait speed assessment up to 60 months after acute respiratory distress syndrome (ARDSNet Long-Term Outcome Study, n = 184; Improving Care of Acute Lung Injury Patients, n = 122).Not applicable.Four-meter gait speed was assessed at 6- and 12-month follow-up (ARDSNet Long-Term Outcome Study) and 36-, 48-, and 60-month follow-up (Improving Care of Acute Lung Injury Patients). Excellent test-retest (intraclass correlation, 0.89-0.99 across studies and follow-up) and inter-rater (intraclass correlation, 0.97) reliability were found. Convergent validity was supported by moderate-to-strong correlations (69% of 32 > 0.40) with other physical function measures. Discriminant validity was supported by weak correlations (86% of 28 < 0.30) with mental health measures. Survivors with impaired versus nonimpaired measures of muscle strength and pulmonary function had significantly slower 4-m gait speed (all but one p < 0.05). Furthermore, 4-m gait speed significantly predicted future hospitalization and health-related quality of life. Gait speed changes were consistent with reported changes in function, supporting responsiveness. The estimated 4-m gait speed minimal important difference was 0.03-0.06 m/s.The 4-m gait speed is a reliable, valid, and responsive measure of physical function in acute respiratory distress syndrome survivors. The estimated minimal important difference will facilitate sample size calculations for clinical studies evaluating the 4-m gait speed test in acute respiratory distress syndrome survivors.

SUBMITTER: Chan KS 

PROVIDER: S-EPMC5206972 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluating Physical Outcomes in Acute Respiratory Distress Syndrome Survivors: Validity, Responsiveness, and Minimal Important Difference of 4-Meter Gait Speed Test.

Chan Kitty S KS   Aronson Friedman Lisa L   Dinglas Victor D VD   Hough Catherine L CL   Morris Peter E PE   Mendez-Tellez Pedro A PA   Jackson James C JC   Ely E Wesley EW   Hopkins Ramona O RO   Needham Dale M DM  

Critical care medicine 20160501 5


<h4>Objective</h4>To examine the reliability, validity, responsiveness, and minimal important difference of the 4-m gait speed test in acute respiratory distress syndrome survivors.<h4>Design</h4>Secondary analyses of data from two longitudinal follow-up studies of acute respiratory distress syndrome survivors. Test-retest and inter-rater reliability, construct validity (convergent, discriminant, and known group), predictive validity, and responsiveness were examined. The minimal important diffe  ...[more]

Similar Datasets

| S-EPMC2816032 | biostudies-literature
| S-EPMC3501248 | biostudies-literature
| S-EPMC5292321 | biostudies-literature
| S-EPMC4420183 | biostudies-literature
| S-EPMC7212132 | biostudies-literature
| S-EPMC7175493 | biostudies-literature
| S-EPMC10613170 | biostudies-literature
| S-EPMC4893131 | biostudies-other
| S-EPMC6400437 | biostudies-literature
| S-EPMC5640407 | biostudies-literature