Unknown

Dataset Information

0

Glucose-responsive hydrogel electrode for biocompatible glucose transistor.


ABSTRACT: In this paper, we propose a highly sensitive and biocompatible glucose sensor using a semiconductor-based field effect transistor (FET) with a functionalized hydrogel. The principle of the FET device contributes to the easy detection of ionic charges with high sensitivity, and the hydrogel coated on the electrode enables the specific detection of glucose with biocompatibility. The copolymerized hydrogel on the Au gate electrode of the FET device is optimized by controlling the mixture ratio of biocompatible 2-hydroxyethylmethacrylate (HEMA) as the main monomer and vinylphenylboronic acid (VPBA) as a glucose-responsive monomer. The gate surface potential of the hydrogel FETs shifts in the negative direction with increasing glucose concentration from 10 ?M to 40 mM, which results from the increase in the negative charges on the basis of the diol-binding of PBA derivatives with glucose molecules in the hydrogel. Moreover, the hydrogel coated on the gate suppresses the signal noise caused by the nonspecific adsorption of proteins such as albumin. The hydrogel FET can serve as a highly sensitive and biocompatible glucose sensor in in vivo or ex vivo applications such as eye contact lenses and sheets adhering to the skin.

SUBMITTER: Kajisa T 

PROVIDER: S-EPMC5256429 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Glucose-responsive hydrogel electrode for biocompatible glucose transistor.

Kajisa Taira T   Sakata Toshiya T  

Science and technology of advanced materials 20170109 1


In this paper, we propose a highly sensitive and biocompatible glucose sensor using a semiconductor-based field effect transistor (FET) with a functionalized hydrogel. The principle of the FET device contributes to the easy detection of ionic charges with high sensitivity, and the hydrogel coated on the electrode enables the specific detection of glucose with biocompatibility. The copolymerized hydrogel on the Au gate electrode of the FET device is optimized by controlling the mixture ratio of b  ...[more]

Similar Datasets

| S-EPMC7412394 | biostudies-literature
| S-EPMC5986559 | biostudies-literature
| S-EPMC6764347 | biostudies-literature
| S-EPMC6190308 | biostudies-literature
| S-EPMC8167660 | biostudies-literature
| S-EPMC8637340 | biostudies-literature
| S-EPMC4553694 | biostudies-literature
| S-EPMC8061386 | biostudies-literature