Unknown

Dataset Information

0

The variability of PCDD/F concentrations in the effluent of wastewater treatment plants with regard to their hydrological environment.


ABSTRACT: The occurrence, concentrations, patterns, and loads of 17 2,3,7,8-substituted congeners of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in treated wastewater collected at the outlets from 14 wastewater treatment plants (WTPs), divided into three size categories. The analysis also considered the effect of wastewater outflow on the final concentrations of PCDDs/Fs, as the samples were collected during flooding and stable hydrological conditions. None of the studied WTPs were found to completely remove toxic congeners of PCDDs/Fs from wastewater: the PCDD concentrations in the outgoing effluent during stable wastewater flow ranged from 2.99 to 177.19 pg/L, PCDFs from 6.05 to 51.30 pg/L, and the Toxic Equivalent (TEQ) was between 0.94 and 4.87 pg/L. The results from high wastewater flow were less diversified, ranging from 5.04 to 8.85 pg/L for PCDDs, from 11.47 to 32.33 pg/L for PCDFs and from 2.00 to 4.65 pg/L for TEQ. The smallest WTPs demonstrated the highest average total and TEQ concentrations due to limited volume, short retention time and outdated technology, and, hence, insufficient treatment efficiency. The largest WTPs have the potential to substantially affect the quality of river water, as despite being associated with the lowest concentrations, they released much greater volumes of treated wastewater and, hence, the greatest amounts of analyzed compounds. Elevated TEQ values were observed at high flow in all WTP size categories indicating the impact of high and stable wastewater flow on the concentrations of the observed PCDDs/Fs.

SUBMITTER: Urbaniak M 

PROVIDER: S-EPMC5285434 | biostudies-literature | 2017 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

The variability of PCDD/F concentrations in the effluent of wastewater treatment plants with regard to their hydrological environment.

Urbaniak Magdalena M   Kiedrzyńska Edyta E   Grochowalski Adam A  

Environmental monitoring and assessment 20170131 2


The occurrence, concentrations, patterns, and loads of 17 2,3,7,8-substituted congeners of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in treated wastewater collected at the outlets from 14 wastewater treatment plants (WTPs), divided into three size categories. The analysis also considered the effect of wastewater outflow on the final concentrations of PCDDs/Fs, as the samples were collected during flooding and stable hydrological condition  ...[more]

Similar Datasets

| S-EPMC7170470 | biostudies-literature
| S-EPMC6245005 | biostudies-literature
| PRJNA437837 | ENA
| PRJNA420645 | ENA
| PRJNA721114 | ENA
| S-EPMC6096557 | biostudies-literature
| S-EPMC5300884 | biostudies-literature
| S-EPMC10091716 | biostudies-literature
| S-EPMC5939699 | biostudies-literature
| S-EPMC7037120 | biostudies-literature