Unknown

Dataset Information

0

Histological assessment of porous custom-made hydroxyapatite implants 6 months and 2.5 years after cranioplasty.


ABSTRACT: BACKGROUND:In cranial reconstruction, the features of artificial bone differ. Custom-made porous hydroxyapatite (HAp) implants for cranioplasty have been used all over the world because of their good cosmetic, biocompatibility, and osteoconductive properties. Surgical techniques were analyzed, and histological assessment of new bone formation in the hydroxyapatite was performed. METHODS:Over a 6-year time period, 41 patients underwent cranioplasty using a custom-made three-dimensional hybrid pore structured hydroxyapatite (3DHPoHAp) implant. The surgical techniques and histological evaluations of 3DHPoHAp in 2 cases, removed 6 months and 2.5 years after cranioplasty, are described. RESULTS:Using 3DHPoHAp, cranioplasty was successfully performed for all patients. The implant fit the bone defect exactly, and surgical manoeuvres were simple and easy. All implants were firmly fixed using a titanium plate, and postoperative infection occurred in 1 patient (2.4%). New bone formation was seen in 2 cases 6 months and 2.5 years after cranioplasty. Osteoblasts were progressing to the stoma at various depths, and bone tissue had ripened. Furthermore, lamellar structure was observed in the case at 2.5 years. CONCLUSIONS:In this study, there was a low infection rate, and new bone formation was seen in vivo after cranioplasty. This study also demonstrated that the 3DHPoHAp implant is a good candidate for cranial bone implants because its good osteoconductivity and biocompatibility.

SUBMITTER: Ono H 

PROVIDER: S-EPMC5288982 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Histological assessment of porous custom-made hydroxyapatite implants 6 months and 2.5 years after cranioplasty.

Ono Hajime H   Sase Taigen T   Tanaka Yuichiro Y   Takasuna Hiroshi H  

Surgical neurology international 20170119


<h4>Background</h4>In cranial reconstruction, the features of artificial bone differ. Custom-made porous hydroxyapatite (HAp) implants for cranioplasty have been used all over the world because of their good cosmetic, biocompatibility, and osteoconductive properties. Surgical techniques were analyzed, and histological assessment of new bone formation in the hydroxyapatite was performed.<h4>Methods</h4>Over a 6-year time period, 41 patients underwent cranioplasty using a custom-made three-dimensi  ...[more]

Similar Datasets

| S-EPMC8913485 | biostudies-literature
| S-EPMC10544156 | biostudies-literature
| S-EPMC7016390 | biostudies-literature
| S-EPMC9213801 | biostudies-literature
| S-EPMC6024979 | biostudies-other
| S-EPMC7116284 | biostudies-literature
| S-EPMC7749502 | biostudies-literature
| S-EPMC5455501 | biostudies-other
| S-EPMC3979890 | biostudies-literature
| S-EPMC9177519 | biostudies-literature