Unknown

Dataset Information

0

Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters.


ABSTRACT: Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-time dosimeters, radiation dose rates were measured on models mimicking a primary operator (PO) and an assistant. Subsequently, a ceiling-suspended lead screen was placed in three commonly used positions to compare the radiation protection efficacy. The radiation exposure to the PO was 2.3 to 227.9 (mean: 67.2?±?49.0) ?Sv/min, with the left anterior oblique (LAO) 45°/cranial 25° and cranial 25° projections causing the highest and the lowest dose rates, respectively. The assistant experienced significantly less radiation overall (mean: 20.1?±?19.6??Sv/min, P?

SUBMITTER: Jia Q 

PROVIDER: S-EPMC5294580 | biostudies-literature | 2017 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters.

Jia Qianjun Q   Chen Ziman Z   Jiang Xianxian X   Zhao Zhenjun Z   Huang Meiping M   Li Jiahua J   Zhuang Jian J   Liu Xiaoqing X   Hu Tianyu T   Liang Wensheng W  

Scientific reports 20170207


Operator radiation and the radiation protection efficacy of a ceiling-suspended lead screen were assessed during coronary angiography (CA) in a catheterization laboratory. An anthropomorphic phantom was placed under the X-ray beam to simulate patient attenuation in eight CA projections. Using real-time dosimeters, radiation dose rates were measured on models mimicking a primary operator (PO) and an assistant. Subsequently, a ceiling-suspended lead screen was placed in three commonly used positio  ...[more]

Similar Datasets

| S-EPMC6865090 | biostudies-literature
| S-EPMC5690001 | biostudies-literature
| S-EPMC8080257 | biostudies-literature
| S-EPMC3371078 | biostudies-other
| S-EPMC7506727 | biostudies-literature
| S-EPMC7796776 | biostudies-literature
| S-EPMC5714524 | biostudies-literature
| S-EPMC5555696 | biostudies-literature
| S-EPMC3739834 | biostudies-other