Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically Ill Patients: A Systematic Review and Meta-Analysis.


ABSTRACT: OBJECTIVE:We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. DATA SOURCES:PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. STUDY SELECTION:Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2?×?2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. DATA EXTRACTION:Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. DATA SYNTHESIS:Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. CONCLUSIONS:Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.

SUBMITTER: Ablordeppey EA 

PROVIDER: S-EPMC5350032 | biostudies-literature | 2017 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically Ill Patients: A Systematic Review and Meta-Analysis.

Ablordeppey Enyo A EA   Drewry Anne M AM   Beyer Alexander B AB   Theodoro Daniel L DL   Fowler Susan A SA   Fuller Brian M BM   Carpenter Christopher R CR  

Critical care medicine 20170401 4


<h4>Objective</h4>We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography.<h4>Data sources</h4>PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov.<h4>Study selection</h4>Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with ches  ...[more]

Similar Datasets

| S-EPMC9541994 | biostudies-literature
| S-EPMC8173448 | biostudies-literature
| S-EPMC1557847 | biostudies-other
| S-EPMC7002808 | biostudies-literature
| S-EPMC5908571 | biostudies-literature
| S-EPMC6790038 | biostudies-literature
| S-EPMC10885043 | biostudies-literature
| S-EPMC6312473 | biostudies-literature
| S-EPMC6797689 | biostudies-literature
| S-EPMC5538097 | biostudies-other