Unknown

Dataset Information

0

Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial.


ABSTRACT: PURPOSE:To assess the accuracy and usability of an electromagnetic navigation system designed to assist Computed Tomography (CT) guided interventions. MATERIALS AND METHODS:120 patients requiring a percutaneous CT intervention (drainage, biopsy, tumor ablation, infiltration, sympathicolysis) were included in this prospective randomized trial. Nineteen radiologists participated. Conventional procedures (CT group) were compared with procedures assisted by a navigation system prototype using an electromagnetic localizer to track the position and orientation of a needle holder (NAV group). The navigation system displays the needle path in real-time on 2D reconstructed CT images extracted from the 3D CT volume. The regional ethics committee approved this study and all patients gave written informed consent. The main outcome was the distance between the planned trajectory and the achieved needle trajectory calculated from the initial needle placement. RESULTS:120 patients were analyzable in intention-to-treat (NAV: 60; CT: 60). Accuracy improved when the navigation system was used: distance error (in millimeters: median[P25%; P75%]) with NAV = 4.1[2.7; 9.1], vs. with CT = 8.9[4.9; 15.1] (p<0.001). After the initial needle placement and first control CT, fewer subsequent CT acquisitions were necessary to reach the target using the navigation system: NAV = 2[2; 3]; CT = 3[2; 4] (p = 0.01). CONCLUSION:The tested system was usable in a standard clinical setting and provided significant improvement in accuracy; furthermore, with the help of navigation, targets could be reached with fewer CT control acquisitions.

SUBMITTER: Durand P 

PROVIDER: S-EPMC5351986 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial.

Durand Pierre P   Moreau-Gaudry Alexandre A   Silvent Anne-Sophie AS   Frandon Julien J   Chipon Emilie E   Médici Maud M   Bricault Ivan I  

PloS one 20170315 3


<h4>Purpose</h4>To assess the accuracy and usability of an electromagnetic navigation system designed to assist Computed Tomography (CT) guided interventions.<h4>Materials and methods</h4>120 patients requiring a percutaneous CT intervention (drainage, biopsy, tumor ablation, infiltration, sympathicolysis) were included in this prospective randomized trial. Nineteen radiologists participated. Conventional procedures (CT group) were compared with procedures assisted by a navigation system prototy  ...[more]

Similar Datasets

| S-EPMC10894390 | biostudies-literature
| S-EPMC7742212 | biostudies-literature
| S-EPMC10529393 | biostudies-literature
| S-EPMC3854600 | biostudies-other
| S-EPMC7294316 | biostudies-literature
| S-EPMC7337196 | biostudies-literature
| S-EPMC8339733 | biostudies-literature
| S-EPMC5532908 | biostudies-other
| S-EPMC8928234 | biostudies-literature
| S-EPMC2565050 | biostudies-other