Unknown

Dataset Information

0

Medium-Chain Chlorinated Paraffins (CPs) Dominate in Australian Sewage Sludge.


ABSTRACT: To simultaneously quantify and profile the complex mixture of short-, median-, and long-chain CPs (SCCPs, MCCPs, and LCCPs) in Australian sewage sludge, we applied and further validated a recently developed novel instrumental technique, using quadrupole time-of-flight high resolution mass spectrometry running in the negative atmospheric pressure chemical ionization mode (APCI-qTOF-HRMS). Without using an analytical column the cleaned extracts were directly injected into the qTOF-HRMS followed by quantification of the CPs by a mathematical algorithm. The recoveries of the four SCCP, MCCP and LCCP-spiked sewage sludge samples ranged from 86 to 123%. This APCI-qTOF-HRMS method is a fast and promising technique for routinely measuring SCCPs, MCCPs, and LCCPs in sewage sludge. Australian sewage sludge was dominated by MCCPs with concentrations ranging from 542 to 3645 ng/g dry weight (dw). Lower SCCPs concentrations (<57-1421 ng/g dw) were detected in the Australian sewage sludge, which were comparable with the LCCPs concentrations (116-960 ng/g dw). This is the first time that CPs were reported in Australian sewage sludge. The results of this study gives a first impression on the distribution of the SCCPs, MCCPs, and LCCPs in Australia wastewater treatment plants (WWTPs).

SUBMITTER: Brandsma SH 

PROVIDER: S-EPMC5362740 | biostudies-literature | 2017 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Medium-Chain Chlorinated Paraffins (CPs) Dominate in Australian Sewage Sludge.

Brandsma Sicco H SH   van Mourik Louise L   O'Brien Jake W JW   Eaglesham Geoff G   Leonards Pim E G PE   de Boer Jacob J   Gallen Christie C   Mueller Jochen J   Gaus Caroline C   Bogdal Christian C  

Environmental science & technology 20170302 6


To simultaneously quantify and profile the complex mixture of short-, median-, and long-chain CPs (SCCPs, MCCPs, and LCCPs) in Australian sewage sludge, we applied and further validated a recently developed novel instrumental technique, using quadrupole time-of-flight high resolution mass spectrometry running in the negative atmospheric pressure chemical ionization mode (APCI-qTOF-HRMS). Without using an analytical column the cleaned extracts were directly injected into the qTOF-HRMS followed by  ...[more]

Similar Datasets

| S-EPMC8610282 | biostudies-literature
| S-EPMC8220329 | biostudies-literature
| S-EPMC7908593 | biostudies-literature
| S-EPMC6931393 | biostudies-literature
| S-EPMC8026443 | biostudies-literature
| S-EPMC7447893 | biostudies-literature
| S-EPMC5556136 | biostudies-literature
| S-EPMC6610544 | biostudies-literature
| S-EPMC7493225 | biostudies-literature
| S-EPMC9910067 | biostudies-literature