Sub-basal Corneal Nerve Plexus Analysis Using a New Software Technology.
Ontology highlight
ABSTRACT: PURPOSE:To study sub-basal corneal nerve plexus (SCNP) parameters by in vivo corneal confocal microscopy using a new software technology and examine the effect of demographics and diabetes mellitus (DM) on corneal nerves morphology. METHODS:A Confoscan 4 (Nidek Technologies) was used in this cross-sectional study to image the SCNP in 84 right eyes at the Miami Veterans Affairs eye clinic. Images were analyzed using a new semiautomated nerve analysis software program (The Corneal Nerve Analysis tool) which evaluated 9 parameters including nerve fibers length (NFL) and nerve fibers length density (NFLD). The main outcome measure was the examination of SCNP morphology by demographics, comorbidities, and HbA1c level. RESULTS:Interoperator and intraoperator reproducibility were good for the 9 parameters studied (Intraclass Correlations [ICCs] 0.73-0.97). Image variability between two images within the same scan was good for all parameters (ICC 0.66-0.80). Older individuals had lower SCNP parameters with NFL and NFLD negatively correlating with age (r=-0.471, and -0.461, respectively, P<0.01 for all). Patients with diabetes had lower mean NFLD 10987.6 ?m/mm (±3,284.6) and NFL 1,289.5 ?m/frame (±387.2) compared with patients without diabetes (mean NFLD 15077.1 ?m/mm [±4,261.3] and NFL 1750.0 ?m/frame [±540.7]) (P<0.05 for all). HbA1c levels in patients with diabetes were inversely correlated with NFL and NFLD (r= -0.568, and -0.569, respectively, P<0.05 for all). CONCLUSIONS:The Corneal Nerve Analysis tool is a reproducible diagnostic software technique for the analysis of the SCNP with confocal microscopy. Older age, DM, and higher level of HbA1c were associated with a significant reduction in SCNP parameters.
SUBMITTER: Batawi H
PROVIDER: S-EPMC5373086 | biostudies-literature | 2018 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA