2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancy.


ABSTRACT:

Purpose

To evaluate the interobserver reproducibility of two-dimensional shear wave elastography (2D-SWE) in measuring liver stiffness (LS) and to investigate factors related to liver 2D-SWE.

Materials and methods

A prospective study was conducted between August 2011 and August 2012 in rheumatoid arthritis patients who had been treated with methotrexate. Interobserver reproducibility of 2D-SWE was evaluated, and the relationship between interobserver difference in LS and related factors was analyzed using linear regression analyses. We considered age, sex, alanine transaminase, cholesterol, body mass index (BMI), and waist circumference as clinical factors, and the mean value of standard deviation (SDM), its difference between two examiners, mean diameter of the regions of interest (ROIM), and its difference in the elasticity map as investigation factors. The cut-off value for significant factors to predict interobserver discrepancies in LS-based fibrosis stage was also inspected.

Results

In total, 176 patients were enrolled. The intraclass correlation coefficient between the two examiners was 0.784. In the univariate analysis, SDM and ROIM were independently associated with interobserver differences in LS as well as BMI, waist circumference, and the difference of ROI, but SDM and ROIM were the only ones significantly related in multivariate analysis (p<0.001 and p = 0.021, respectively). The best cut-off value for SDM in predicting interobserver discrepancy in LS-based fibrosis stage was 1.4.

Conclusions

Interobserver reproducibility of 2D-SWE for measuring LS was good and SDM was the most significantly associated factor with interobserver differences in LS and interobserver discordance in LS-based fibrosis stage.

SUBMITTER: Yoon K 

PROVIDER: S-EPMC5393601 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancy.

Yoon Kibo K   Jeong Woo Kyoung WK   Kim Yongsoo Y   Kim Min Yeong MY   Kim Tae Yeob TY   Sohn Joo Hyun JH  

PloS one 20170417 4


<h4>Purpose</h4>To evaluate the interobserver reproducibility of two-dimensional shear wave elastography (2D-SWE) in measuring liver stiffness (LS) and to investigate factors related to liver 2D-SWE.<h4>Materials and methods</h4>A prospective study was conducted between August 2011 and August 2012 in rheumatoid arthritis patients who had been treated with methotrexate. Interobserver reproducibility of 2D-SWE was evaluated, and the relationship between interobserver difference in LS and related f  ...[more]

Similar Datasets

| S-EPMC7466577 | biostudies-literature
| S-EPMC9179262 | biostudies-literature
| S-EPMC8830801 | biostudies-literature
| S-EPMC7880611 | biostudies-literature
| S-EPMC8761995 | biostudies-literature
| S-EPMC8504217 | biostudies-literature
| S-EPMC10521701 | biostudies-literature
| S-EPMC11320539 | biostudies-literature
| S-EPMC7103049 | biostudies-literature
| S-EPMC8026049 | biostudies-literature