Is the Assessment of 5 Meters of Gait with a Single Body-Fixed-Sensor Enough to Recognize Idiopathic Parkinson's Disease-Associated Gait?


ABSTRACT: Quantitative assessment of gait in patients with Parkinson's disease (PD) is an important step in addressing motor symptoms and improving clinical management. Based on the assessment of only 5 meters of gait with a single body-fixed-sensor placed on the lower back, this study presents a method for the identification of step-by-step kinematic parameters in 14 healthy controls and in 28 patients at early-to-moderate stages of idiopathic PD. Differences between groups in step-by-step kinematic parameters were evaluated to understand gait impairments in the PD group. Moreover, a discriminant model between groups was built from a subset of significant and independent parameters and based on a 10-fold cross-validated model. The discriminant model correctly classified a total of 89.5% participants with four kinematic parameters. The sensitivity of the model was 95.8% and the specificity 78.6%. The results indicate that the proposed method permitted to reasonably recognize idiopathic PD-associated gait from 5-m walking assessments. This motivates further investigation on the clinical utility of short episodes of gait assessment with body-fixed-sensors.

SUBMITTER: Mico-Amigo ME 

PROVIDER: S-EPMC5397518 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is the Assessment of 5 Meters of Gait with a Single Body-Fixed-Sensor Enough to Recognize Idiopathic Parkinson's Disease-Associated Gait?

Micó-Amigo M E ME   Kingma I I   Faber G S GS   Kunikoshi A A   van Uem J M T JMT   van Lummel R C RC   Maetzler W W   van Dieën J H JH  

Annals of biomedical engineering 20170120 5


Quantitative assessment of gait in patients with Parkinson's disease (PD) is an important step in addressing motor symptoms and improving clinical management. Based on the assessment of only 5 meters of gait with a single body-fixed-sensor placed on the lower back, this study presents a method for the identification of step-by-step kinematic parameters in 14 healthy controls and in 28 patients at early-to-moderate stages of idiopathic PD. Differences between groups in step-by-step kinematic para  ...[more]

Similar Datasets

| S-EPMC6389786 | biostudies-literature
| S-EPMC4011791 | biostudies-literature
| S-EPMC6545579 | biostudies-literature
| S-EPMC4627774 | biostudies-literature
| S-EPMC3726691 | biostudies-literature
| S-EPMC9386067 | biostudies-literature
| S-EPMC5391956 | biostudies-literature
| S-EPMC10303817 | biostudies-literature
| S-EPMC11208588 | biostudies-literature
| S-EPMC9382193 | biostudies-literature