Unknown

Dataset Information

0

Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.


ABSTRACT: Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690?cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation for AF.Retrospective analysis of data on 133 patients who underwent AF catheter ablation with 3-D electro-anatomic mapping at our institute from January 2014 to May 2015 was performed. Since January 2014, fluoroscopy frame rate of 4-FPS was implemented at our institute, which was further decreased to 2-FPS in September 2014. We compared the radiation exposure quantified as dose area product (DAP) and effective dose (ED) between the 4-FPS (n?=?57) and 2-FPS (n?=?76) groups.The 4-FPS group showed higher median DAP (599.9?cGy cm; interquartile range [IR], 371.4-1337.5?cGy cm vs. 392.0?cGy cm; IR, 289.7-591.4?cGy cm; P?

SUBMITTER: Lee JH 

PROVIDER: S-EPMC5478349 | biostudies-literature | 2017 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.

Lee Ji Hyun JH   Kim Jun J   Kim Minsu M   Hwang Jongmin J   Hwang You Mi YM   Kang Joon-Won JW   Nam Gi-Byoung GB   Choi Kee-Joon KJ   Kim You-Ho YH  

Medicine 20170601 24


Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690 cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation fo  ...[more]

Similar Datasets

| S-EPMC7733568 | biostudies-literature
| S-EPMC4570247 | biostudies-literature
| S-EPMC8919640 | biostudies-literature
| S-EPMC5728981 | biostudies-literature
| S-EPMC6393682 | biostudies-literature
| S-EPMC7533126 | biostudies-literature
| S-EPMC6476416 | biostudies-literature
| S-EPMC6177159 | biostudies-literature
| S-EPMC8637076 | biostudies-literature
| S-EPMC6232922 | biostudies-literature