Application of Zone Model Predictive Control Artificial Pancreas During Extended Use of Infusion Set and Sensor: A Randomized Crossover-Controlled Home-Use Trial.


ABSTRACT: OBJECTIVE:As artificial pancreas (AP) becomes standard of care, consideration of extended use of insulin infusion sets (IIS) and continuous glucose monitors (CGMs) becomes vital. We conducted an outpatient randomized crossover study to test the safety and efficacy of a zone model predictive control (zone-MPC)-based AP system versus sensor augmented pump (SAP) therapy in which IIS and CGM failures were provoked via extended wear to 7 and 21 days, respectively. RESEARCH DESIGN AND METHODS:A smartphone-based AP system was used by 19 adults (median age 23 years [IQR 10], mean 8.0 ± 1.7% HbA1c) over 2 weeks and compared with SAP therapy for 2 weeks in a crossover, unblinded outpatient study with remote monitoring in both study arms. RESULTS:AP improved percent time 70-140 mg/dL (48.1 vs. 39.2%; P = 0.016) and time 70-180 mg/dL (71.6 vs. 65.2%; P = 0.008) and decreased median glucose (141 vs. 153 mg/dL; P = 0.036) and glycemic variability (SD 52 vs. 55 mg/dL; P = 0.044) while decreasing percent time <70 mg/dL (1.3 vs. 2.7%; P = 0.001). AP also improved overnight control, as measured by mean glucose at 0600 h (140 vs. 158 mg/dL; P = 0.02). IIS failures (1.26 ± 1.44 vs. 0.78 ± 0.78 events; P = 0.13) and sensor failures (0.84 ± 0.6 vs. 1.1 ± 0.73 events; P = 0.25) were similar between AP and SAP arms. Higher percent time in closed loop was associated with better glycemic outcomes. CONCLUSIONS:Zone-MPC significantly and safely improved glycemic control in a home-use environment despite prolonged CGM and IIS wear. This project represents the first home-use AP study attempting to provoke and detect component failure while successfully maintaining safety and effective glucose control.

SUBMITTER: Forlenza GP 

PROVIDER: S-EPMC5521973 | biostudies-literature | 2017 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Application of Zone Model Predictive Control Artificial Pancreas During Extended Use of Infusion Set and Sensor: A Randomized Crossover-Controlled Home-Use Trial.

Forlenza Gregory P GP   Deshpande Sunil S   Ly Trang T TT   Howsmon Daniel P DP   Cameron Faye F   Baysal Nihat N   Mauritzen Eric E   Marcal Tatiana T   Towers Lindsey L   Bequette B Wayne BW   Huyett Lauren M LM   Pinsker Jordan E JE   Gondhalekar Ravi R   Doyle Francis J FJ   Maahs David M DM   Buckingham Bruce A BA   Dassau Eyal E  

Diabetes care 20170605 8


<h4>Objective</h4>As artificial pancreas (AP) becomes standard of care, consideration of extended use of insulin infusion sets (IIS) and continuous glucose monitors (CGMs) becomes vital. We conducted an outpatient randomized crossover study to test the safety and efficacy of a zone model predictive control (zone-MPC)-based AP system versus sensor augmented pump (SAP) therapy in which IIS and CGM failures were provoked via extended wear to 7 and 21 days, respectively.<h4>Research design and metho  ...[more]

Similar Datasets

| S-EPMC7906861 | biostudies-literature
| S-EPMC6154252 | biostudies-literature
| S-EPMC5008188 | biostudies-literature
| S-EPMC9353978 | biostudies-literature
| S-EPMC4915560 | biostudies-literature
| S-EPMC6909715 | biostudies-literature
| S-EPMC5358809 | biostudies-literature
| S-EPMC4067397 | biostudies-literature
| S-EPMC6760658 | biostudies-literature
| S-EPMC4029139 | biostudies-literature