Unknown

Dataset Information

0

A rapid, low-cost, and microfluidic chip-based system for parallel identification of multiple pathogens related to clinical pneumonia.


ABSTRACT: An air-insulated microfluidic chip was designed for the automatic centrifugal distribution of samples to 24-test cells, enabling the parallel identification of multiple clinical pneumonia-related pathogens in 1.45-?L reactions without cross-contamination in 45?min. A portable nucleic acid analyzer that integrates mechanical, confocal optical, electronic, and software functions was also developed to collect fluorescence data in a Ø3 mm imaging field near the optical diffraction limit for highly sensitive fluorescence detection of nucleic acid amplification in real time. This microfluidic chip-based portable nucleic acid analyzer could detect low abundance nucleic acids present at as few as 10 copies. In a blinded experiment, specific identification of Mycoplasma pneumoniae, Staphylococcus aureus, and methicillin-resistant S. aureus was achieved with 229 clinical patient sputum samples. The total coincidence rate of our system and traditional RT-PCR with an ABI 7500 was 99.56%. Four samples accounting for the 0.44% inconformity were retested by gene sequencing, revealing that our system reported the correct results. This novel microfluidic chip-based detection system is cost-effective, rapid, sensitive, specific, and has a relatively high throughput for parallel identification, which is especially suitable for resource-limited facilities/areas and point-of-care testing.

SUBMITTER: Huang G 

PROVIDER: S-EPMC5527024 | biostudies-literature | 2017 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

A rapid, low-cost, and microfluidic chip-based system for parallel identification of multiple pathogens related to clinical pneumonia.

Huang Guoliang G   Huang Qin Q   Xie Lan L   Xiang Guangxin G   Wang Lei L   Xu Hui H   Ma Li L   Luo Xianbo X   Xin Juan J   Zhou Xinying X   Jin Xiangyu X   Zhang Lei L  

Scientific reports 20170725 1


An air-insulated microfluidic chip was designed for the automatic centrifugal distribution of samples to 24-test cells, enabling the parallel identification of multiple clinical pneumonia-related pathogens in 1.45-μL reactions without cross-contamination in 45 min. A portable nucleic acid analyzer that integrates mechanical, confocal optical, electronic, and software functions was also developed to collect fluorescence data in a Ø3 mm imaging field near the optical diffraction limit for highly s  ...[more]

Similar Datasets

| S-EPMC7569958 | biostudies-literature
| S-EPMC7829496 | biostudies-literature
| S-EPMC5362183 | biostudies-literature
| S-EPMC9616700 | biostudies-literature
| S-EPMC6952809 | biostudies-literature
| S-EPMC5726975 | biostudies-literature
| S-EPMC6019315 | biostudies-literature
| S-EPMC6481316 | biostudies-literature
| S-EPMC10562543 | biostudies-literature
| S-EPMC3377543 | biostudies-literature