Unknown

Dataset Information

0

Improvement of a rapid diagnostic application of monoclonal antibodies against avian influenza H7 subtype virus using Europium nanoparticles.


ABSTRACT: The development of a sensitive and rapid diagnostic test is needed for early detection of avian influenza (AI) H7 subtype. In this study, novel monoclonal antibodies (mAbs) against influenza A H7N9 recombinant hemagglutinin (rHA)1 were developed and applied to a Europium nanoparticle-based rapid fluorescent immunochromatographic strip test (FICT) to improve the sensitivity of the rapid diagnostic system. Two antibodies (2F4 and 6D7) exhibited H7 subtype specificity in a dot-FICT assay by optimization of the conjugate and the pH of the lysis buffer. The subtype specificity was confirmed by an immunofluorescence assay and Western blot analysis. The limit of detection of the FICT employing novel mAbs 31 ng/mL for H7N9 rHA1 and 40 hemagglutination units/mL for H7 subtype virus. Sensitivity was improved 25-fold using Europium as confirmed by comparison of colloidal gold-based rapid diagnostic kit using the 2F4 and 6D7 mAbs.

SUBMITTER: Yeo SJ 

PROVIDER: S-EPMC5554140 | biostudies-literature | 2017 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improvement of a rapid diagnostic application of monoclonal antibodies against avian influenza H7 subtype virus using Europium nanoparticles.

Yeo Seon-Ju SJ   Bao Duong Tuan DT   Seo Ga-Eun GE   Bui Cuc Thi CT   Kim Do Thi Hoang DTH   Anh Nguyen Thi Viet NTV   Tien Trinh Thi Thuy TTT   Linh Nguyen Thi Phuong NTP   Sohn Hae-Jin HJ   Chong Chom-Kyu CK   Shin Ho-Joon HJ   Park Hyun H  

Scientific reports 20170811 1


The development of a sensitive and rapid diagnostic test is needed for early detection of avian influenza (AI) H7 subtype. In this study, novel monoclonal antibodies (mAbs) against influenza A H7N9 recombinant hemagglutinin (rHA)1 were developed and applied to a Europium nanoparticle-based rapid fluorescent immunochromatographic strip test (FICT) to improve the sensitivity of the rapid diagnostic system. Two antibodies (2F4 and 6D7) exhibited H7 subtype specificity in a dot-FICT assay by optimiz  ...[more]

Similar Datasets

| S-EPMC7852141 | biostudies-literature
| S-EPMC6026626 | biostudies-literature
| S-EPMC8025375 | biostudies-literature
| S-EPMC2661249 | biostudies-literature
| S-EPMC2045456 | biostudies-literature
| S-EPMC3630491 | biostudies-other
| S-EPMC5769215 | biostudies-literature
| S-EPMC5525275 | biostudies-literature
| S-EPMC7120348 | biostudies-literature
| S-EPMC3141685 | biostudies-literature