Unknown

Dataset Information

0

Up to 52 administrations of macrocyclic ionic MR contrast agent are not associated with intracranial gadolinium deposition: Multifactorial analysis in 385 patients.


ABSTRACT:

Purpose

To determine whether multiple repeated administrations of gadolinium-based macrocyclic ionic MR contrast agent (MICA) are associated with intracranial gadolinium deposition and identify the predisposing factors for deposition in various clinical situations.

Materials and methods

In this institutional review board-approved retrospective study, 385 consecutive patients who underwent MICA-enhanced MR imaging were enrolled. The dentate nucleus-to-pons (DN/P) and globus pallidus-to-thalamus (GP/Th) signal intensity (SI) ratios on unenhanced T1-weighted images were recorded by 2 independent readers and averaged. The mean DN/P and GP/Th SI ratio difference between the last and the first examinations were tested using the one-sample t-test. Student's t-test and stepwise regression analysis were used to identify the predisposing factors for deposition based on the number of administrations, time interval, hepatic and renal function, magnetic field strength, and chemo- or radiation therapy.

Results

The mean DN/P SI ratio difference was not different from zero (P = .697), even in patients with ?20 administrations (n = 33). Only patients with abnormal renal function showed an increase in the mean DN/P SI ratio difference (P = .019). The mean DN/P SI ratio difference was not associated with any predisposing factors. However, the mean GP/Th SI ratio difference showed decrease (P < .001), which was associated with age (P = .007), number of administrations (P = .01) and number of radiation therapy sessions (P = .022) on multivariate analysis.

Conclusion

Multiple repeated administrations of MICA were not associated with increased T1 signal intensity in deep brain nuclei suggestive of Gd deposition in patients with normal renal function.

SUBMITTER: Lee JY 

PROVIDER: S-EPMC5578663 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Up to 52 administrations of macrocyclic ionic MR contrast agent are not associated with intracranial gadolinium deposition: Multifactorial analysis in 385 patients.

Lee Ji Ye JY   Park Ji Eun JE   Kim Ho Sung HS   Kim Seon-Ok SO   Oh Joo Young JY   Shim Woo Hyun WH   Jung Seung Chai SC   Choi Choong Gon CG   Kim Sang Joon SJ  

PloS one 20170831 8


<h4>Purpose</h4>To determine whether multiple repeated administrations of gadolinium-based macrocyclic ionic MR contrast agent (MICA) are associated with intracranial gadolinium deposition and identify the predisposing factors for deposition in various clinical situations.<h4>Materials and methods</h4>In this institutional review board-approved retrospective study, 385 consecutive patients who underwent MICA-enhanced MR imaging were enrolled. The dentate nucleus-to-pons (DN/P) and globus pallidu  ...[more]

Similar Datasets

| S-EPMC5836870 | biostudies-literature
| S-EPMC5605029 | biostudies-other
| S-EPMC7655291 | biostudies-literature
| S-EPMC7581952 | biostudies-literature
| S-EPMC5417580 | biostudies-literature
| S-EPMC6709999 | biostudies-literature
| S-EPMC8369451 | biostudies-literature
| S-EPMC4720435 | biostudies-literature
| S-EPMC4228714 | biostudies-literature
| S-EPMC7965223 | biostudies-literature