Unknown

Dataset Information

0

Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts using a 2D-LC/2D-GC system: a method translation from two FIDs to two MS detectors.


ABSTRACT: An online two-dimensional (2D) liquid chromatography/2D gas chromatography system with two mass-selective detectors has been developed on the basis of a previous system with two flame ionization detectors. The method translation involved the change of carrier gas from hydrogen to helium, column dimension and detectors. The 2D system with two mass-selective detectors was validated with use of polycyclic aromatic hydrocarbon (PAH) standards and two standard reference materials from air and diesel exhaust. Furthermore, the system was applied to a real sample, wood smoke particulates. The PAH values determined correlated well with the previous data and those from the National Institute of Standards and Technology. The system enhanced the benefits of the previous system, which were limited by the low detectability and lack of mass selectivity. This study shows an automated 2D system that is valid for PAH analysis of complex environmental samples directly from crude extracts. Graphical Abstract Schematic illustration showing on-line clean-up, separation and detection using 2D-LC/2D-GC/MS.

SUBMITTER: Lim H 

PROVIDER: S-EPMC5583270 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts using a 2D-LC/2D-GC system: a method translation from two FIDs to two MS detectors.

Lim Hwanmi H   Ahmed Trifa M TM   Bergvall Christoffer C   Westerholm Roger R  

Analytical and bioanalytical chemistry 20170724 24


An online two-dimensional (2D) liquid chromatography/2D gas chromatography system with two mass-selective detectors has been developed on the basis of a previous system with two flame ionization detectors. The method translation involved the change of carrier gas from hydrogen to helium, column dimension and detectors. The 2D system with two mass-selective detectors was validated with use of polycyclic aromatic hydrocarbon (PAH) standards and two standard reference materials from air and diesel  ...[more]

Similar Datasets

| S-EPMC4300434 | biostudies-literature
2013-07-22 | GSE49068 | GEO
| S-EPMC6899884 | biostudies-literature
| S-EPMC5474056 | biostudies-literature
| PRJNA590550 | ENA
2012-04-18 | GSE37326 | GEO
| S-EPMC2830011 | biostudies-literature
2013-07-22 | E-GEOD-49068 | biostudies-arrayexpress
| S-EPMC8580896 | biostudies-literature
| S-EPMC4113342 | biostudies-literature