Stacking-fault strengthening of biomedical Co-Cr-Mo alloy via multipass thermomechanical processing.


ABSTRACT: The strengthening of metallic biomaterials, such as Co-Cr-Mo and titanium alloys, is of crucial importance to the improvement of the durability of orthopedic implants. In the present study, we successfully developed a face-centered cubic (fcc) Co-Cr-Mo alloy with an extremely high yield strength (1400 MPa) and good ductility (12%) by multipass hot-rolling, which is suitable for industrial production, and examined the relevant strengthening mechanisms. Using an X-ray diffraction line-profile analysis, we revealed that a substantial increase in the number of stacking faults (SFs) in the fcc γ-matrix occurred at a greater height reduction (r), while physical modeling demonstrated that the contribution of the accumulated SFs (i.e., the reduction in SF spacing) with an increase in r successfully explains the entire strengthening behavior of the hot-rolled alloy. The present study sheds light on the importance of the SF strengthening mechanism, and will help to guide the design and manufacturing strategy for the high-strength Co-Cr-Mo alloys used in highly durable medical devices.

SUBMITTER: Yamanaka K 

PROVIDER: S-EPMC5589849 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Stacking-fault strengthening of biomedical Co-Cr-Mo alloy via multipass thermomechanical processing.

Yamanaka Kenta K   Mori Manami M   Sato Shigeo S   Chiba Akihiko A  

Scientific reports 20170907 1


The strengthening of metallic biomaterials, such as Co-Cr-Mo and titanium alloys, is of crucial importance to the improvement of the durability of orthopedic implants. In the present study, we successfully developed a face-centered cubic (fcc) Co-Cr-Mo alloy with an extremely high yield strength (1400 MPa) and good ductility (12%) by multipass hot-rolling, which is suitable for industrial production, and examined the relevant strengthening mechanisms. Using an X-ray diffraction line-profile anal  ...[more]

Similar Datasets

| S-EPMC7747568 | biostudies-literature
| S-EPMC5075899 | biostudies-other
| S-EPMC7033204 | biostudies-literature
| S-EPMC7779754 | biostudies-literature
| S-EPMC10533813 | biostudies-literature
| S-EPMC8196205 | biostudies-literature
| S-EPMC6987211 | biostudies-literature
| S-EPMC6651660 | biostudies-literature
| S-EPMC6397269 | biostudies-literature
| S-EPMC7287112 | biostudies-literature