Recovery of Proprioception in the Upper Extremity by Robotic Mirror Therapy: a Clinical Pilot Study for Proof of Concept.


ABSTRACT: A novel robotic mirror therapy system was recently developed to provide proprioceptive stimulus to the hemiplegic arm during a mirror therapy. Validation of the robotic mirror therapy system was performed to confirm its synchronicity prior to the clinical study. The mean error angle range between the intact arm and the robot was 1.97 to 4.59 degrees. A 56-year-old male who had right middle cerebral artery infarction 11 months ago received the robotic mirror therapy for ten 30-minute sessions during 2 weeks. Clinical evaluation and functional magnetic resonance imaging (fMRI) studies were performed before and after the intervention. At the follow-up evaluation, the thumb finding test score improved from 2 to 1 for eye level and from 3 to 1 for overhead level. The Albert's test score on the left side improved from 6 to 11. Improvements were sustained at 2-month follow-up. The fMRI during the passive motion revealed a considerable increase in brain activity at the lower part of the right superior parietal lobule, suggesting the possibility of proprioception enhancement. The robotic mirror therapy system may serve as a useful treatment method for patients with supratentorial stroke to facilitate recovery of proprioceptive deficit and hemineglect.

SUBMITTER: Nam HS 

PROVIDER: S-EPMC5592168 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Recovery of Proprioception in the Upper Extremity by Robotic Mirror Therapy: a Clinical Pilot Study for Proof of Concept.

Nam Hyung Seok HS   Koh Sukgyu S   Beom Jaewon J   Kim Yoon Jae YJ   Park Jang Woo JW   Koh Eun Sil ES   Chung Sun Gun SG   Kim Sungwan S  

Journal of Korean medical science 20171001 10


A novel robotic mirror therapy system was recently developed to provide proprioceptive stimulus to the hemiplegic arm during a mirror therapy. Validation of the robotic mirror therapy system was performed to confirm its synchronicity prior to the clinical study. The mean error angle range between the intact arm and the robot was 1.97 to 4.59 degrees. A 56-year-old male who had right middle cerebral artery infarction 11 months ago received the robotic mirror therapy for ten 30-minute sessions dur  ...[more]

Similar Datasets

| S-EPMC6697203 | biostudies-literature
| S-EPMC5877860 | biostudies-literature
| S-EPMC6817341 | biostudies-literature
| S-EPMC6033222 | biostudies-literature
| S-EPMC4431803 | biostudies-literature
| S-EPMC8268536 | biostudies-literature
| S-EPMC8186017 | biostudies-literature
| S-EPMC4782664 | biostudies-literature
| S-EPMC9541110 | biostudies-literature
| S-EPMC5469353 | biostudies-literature