Unknown

Dataset Information

0

Genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food.


ABSTRACT: Here, we conducted in vitro genotoxicity tests to evaluate the genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food. Styrene oligomers were extracted with acetone and the extract was subjected to the Ames test (OECD test guideline No. 471) and the in vitro chromosomal aberration test (OECD test guideline No. 473) under good laboratory practice conditions. The concentrations of styrene dimers and trimers in the concentrated extract were 540 and 13,431 ppm, respectively. Extraction with acetone provided markedly higher concentrations of styrene oligomers compared with extraction with 50% ethanol aqueous solution, which is the food simulant currently recommended for use in safety assessments of polystyrene by both the United States Food and Drug Administration and the European Food Safety Authority. And these high concentrations of styrene dimers and trimers were utilized for the evaluation of genotoxicity in vitro. Ames tests using five bacterial tester strains were negative both in the presence or absence of metabolic activation. The in vitro chromosomal aberration test using Chinese hamster lung cells (CHL/IU) was also negative. Together, these results suggest that the risk of the genotoxicity of styrene oligomers that migrate from polystyrene food packaging into food is very low.

SUBMITTER: Nakai M 

PROVIDER: S-EPMC5598101 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food.

Nakai Makoto M   Tsubokura Mifumi M   Suzuki Masaru M   Fujishima Saori S   Watanabe Yoichi Y   Hasegawa Yu Y   Oyama Kazuhiro K   Ogura Shozo S  

Toxicology reports 20141115


Here, we conducted <i>in vitro</i> genotoxicity tests to evaluate the genotoxicity of styrene oligomers extracted from polystyrene intended for use in contact with food. Styrene oligomers were extracted with acetone and the extract was subjected to the Ames test (OECD test guideline No. 471) and the <i>in vitro</i> chromosomal aberration test (OECD test guideline No. 473) under good laboratory practice conditions. The concentrations of styrene dimers and trimers in the concentrated extract were  ...[more]

Similar Datasets

| S-EPMC9376037 | biostudies-literature
| S-EPMC7848699 | biostudies-literature
| S-EPMC8301662 | biostudies-literature
| S-EPMC8160766 | biostudies-literature
| S-EPMC9742862 | biostudies-literature
| S-EPMC7074339 | biostudies-literature
| S-EPMC6572652 | biostudies-literature
| S-EPMC6311025 | biostudies-literature
| S-EPMC6882904 | biostudies-literature
| S-EPMC4398494 | biostudies-literature