Unknown

Dataset Information

0

Intra and inter-session reliability of rapid Transcranial Magnetic Stimulation stimulus-response curves of tibialis anterior muscle in healthy older adults.


ABSTRACT:

Objective

The clinical use of Transcranial Magnetic Stimulation (TMS) as a technique to assess corticospinal excitability is limited by the time for data acquisition and the measurement variability. This study aimed at evaluating the reliability of Stimulus-Response (SR) curves acquired with a recently proposed rapid protocol on tibialis anterior muscle of healthy older adults.

Methods

Twenty-four neurologically-intact adults (age:55-75 years) were recruited for this test-retest study. During each session, six SR curves, 3 at rest and 3 during isometric muscle contractions at 5% of maximum voluntary contraction (MVC), were acquired. Motor Evoked Potentials (MEPs) were normalized to the maximum peripherally evoked response; the coil position and orientation were monitored with an optical tracking system. Intra- and inter-session reliability of motor threshold (MT), area under the curve (AURC), MEPmax, stimulation intensity at which the MEP is mid-way between MEPmax and MEPmin (I50), slope in I50, MEP latency, and silent period (SP) were assessed in terms of Standard Error of Measurement (SEM), relative SEM, Minimum Detectable Change (MDC), and Intraclass Correlation Coefficient (ICC).

Results

The relative SEM was ?10% for MT, I50, latency and SP both at rest and 5%MVC, while it ranged between 11% and 37% for AURC, MEPmax, and slope. MDC values were overall quite large; e.g., MT required a change of 12%MSO at rest and 10%MSO at 5%MVC to be considered a real change. Inter-sessions ICC were >0.6 for all measures but slope at rest and MEPmax and latency at 5%MVC.

Conclusions

Measures derived from SR curves acquired in <4 minutes are affected by similar measurement errors to those found with long-lasting protocols, suggesting that the rapid method is at least as reliable as the traditional methods. As specifically designed to include older adults, this study provides normative data for future studies involving older neurological patients (e.g. stroke survivors).

SUBMITTER: Peri E 

PROVIDER: S-EPMC5599029 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Intra and inter-session reliability of rapid Transcranial Magnetic Stimulation stimulus-response curves of tibialis anterior muscle in healthy older adults.

Peri Elisabetta E   Ambrosini Emilia E   Colombo Vera Maria VM   van de Ruit Mark M   Grey Michael J MJ   Monticone Marco M   Ferriero Giorgio G   Pedrocchi Alessandra A   Ferrigno Giancarlo G   Ferrante Simona S  

PloS one 20170914 9


<h4>Objective</h4>The clinical use of Transcranial Magnetic Stimulation (TMS) as a technique to assess corticospinal excitability is limited by the time for data acquisition and the measurement variability. This study aimed at evaluating the reliability of Stimulus-Response (SR) curves acquired with a recently proposed rapid protocol on tibialis anterior muscle of healthy older adults.<h4>Methods</h4>Twenty-four neurologically-intact adults (age:55-75 years) were recruited for this test-retest s  ...[more]

Similar Datasets

| S-EPMC7226675 | biostudies-literature
| S-EPMC7351217 | biostudies-literature
| S-EPMC8335644 | biostudies-literature
| S-EPMC7442336 | biostudies-literature
| S-EPMC5890217 | biostudies-literature
| S-EPMC4426257 | biostudies-literature
| S-EPMC4560445 | biostudies-literature
| S-EPMC10499933 | biostudies-literature
| S-EPMC4574708 | biostudies-literature
| S-EPMC5368166 | biostudies-literature