Unknown

Dataset Information

0

In vivo imaging system for explants analysis-A new approach for assessment of cell transplantation effects in large animal models.


ABSTRACT: Despite spectacular progress in cellular transplantology, there are still many concerns about the fate of transplanted cells. More preclinical studies are needed, especially on large animal models, to bridge the translational gap between basic research and the clinic. Herein, we propose a novel approach in analysis of cell transplantation effects in large animals explants using in vivo imaging system (IVIS®) or similar equipment.In the in vitro experiment cells labeled with fluorescent membrane dyes: DID (far red) or PKH26 (orange) were visualized with IVIS®. The correlation between the fluorescence signal and cell number with or without addition of minced muscle tissue was calculated. In the ex vivo study urethras obtained from goats after intraurethral cells (n = 9) or PBS (n = 4) injections were divided into 0.5 cm cross-slices and analyzed by using IVIS®. Automatic algorithm followed or not by manual setup was used to separate specific dye signal from tissue autofluorescence. The results were verified by systematic microscopic analysis of standard 10 ?m specimens prepared from slices before and after immunohistochemical staining. Comparison of obtained data was performed using diagnostic test function.Fluorescence signal strength in IVIS® was directly proportional to the number of cells regardless of the dye used and detectable for minimum 0.25x106 of cells. DID-derived signal was much less affected by the background signal in comparison to PKH26 in in vitro test. Using the IVIS® to scan explants in defined arrangement resulted in precise localization of DID but not PKH26 positive spots. Microscopic analysis of histological specimens confirmed the specificity (89%) and sensitivity (80%) of IVIS® assessment relative to DID dye. The procedure enabled successful immunohistochemical staining of specimens derived from analyzed slices.The IVIS® system under appropriate conditions of visualization and analysis can be used as a method for ex vivo evaluation of cell transplantation effects. Presented protocol allows for evaluation of cell delivery precision rate, enables semi-quantitative assessment of signal, preselects material for further analysis without interfering with the tissue properties. Far red dyes are appropriate fluorophores to cell labeling for this application.

SUBMITTER: Zarychta-Wisniewska W 

PROVIDER: S-EPMC5607129 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

In vivo imaging system for explants analysis-A new approach for assessment of cell transplantation effects in large animal models.

Zarychta-Wiśniewska Weronika W   Burdzinska Anna A   Zagozdzon Radosław R   Dybowski Bartosz B   Butrym Marta M   Gajewski Zdzisław Z   Paczek Leszek L  

PloS one 20170920 9


<h4>Introduction</h4>Despite spectacular progress in cellular transplantology, there are still many concerns about the fate of transplanted cells. More preclinical studies are needed, especially on large animal models, to bridge the translational gap between basic research and the clinic. Herein, we propose a novel approach in analysis of cell transplantation effects in large animals explants using in vivo imaging system (IVIS®) or similar equipment.<h4>Material and methods</h4>In the in vitro e  ...[more]

Similar Datasets

| S-EPMC5221575 | biostudies-literature
| S-EPMC10140170 | biostudies-literature
| S-EPMC3703647 | biostudies-literature
| S-EPMC4834612 | biostudies-literature
| S-EPMC8571486 | biostudies-literature
| S-EPMC4737318 | biostudies-other
2017-05-27 | GSE98995 | GEO
| S-EPMC8811588 | biostudies-literature
| S-EPMC5711340 | biostudies-literature
| S-EPMC6263979 | biostudies-literature